Download Print this page

Installation Instructions - GE RAK4157 Installation Instructions

Power supply kit for direct connection
Hide thumbs Also See for RAK4157:

Advertisement

2800 & 3800 SERIES – DIRECT ELECTRICAL CONNECTION
Order separately the RAK4002A Kit. This kit must be used in
this application.
1. CONNECT THE CORDSET
Plug the connector, provided in the Direct Connect Kit, fully
into place in the unit mating connector. Be sure the locking
tabs at the sides are engaged.
Connector
2. ATTACH CONDUIT
1. Use the round knockout at the bottom of the junction
box to attach conduit coming from the branch circuit.
Remove the knockout, attach the conduit and bring
wires into the junction box. Leave 6" of wire free at the
end of the conduit to allow connections to be made.
2. If a fuse and fuseholder are to be used, the
knockout at the top of the box is for mounting a Buss
Fuseholder. Be sure the fuse and fuseholder are of
the same rating as the branch circuit. Leadwires at the
fuse can be either soldered in place or attached using
UL-listed 1/4" female (receptacle) crimp connectors.

Installation Instructions

Conduit
3. INSTALL JUNCTION BOX
• Install the junction box by engaging the left tabs on the
lower right face of the unit, aligning the screw holes at
the top and bottom and driving the two screws until
secure. Be sure that all wire leads are inside the box and
not pinched between the box and the unit. The green
insulated ground wire from the unit MUST be connected
to the branch circuit ground wire.
Make all wire connections by using appropriate UL-listed
electrical connectors and techniques (black to black,
white to white and green to green).
4. INSTALL JUNCTION BOX COVER
1. Carefully tuck all wires and connections back
inside the junction box. Be sure there are no loose
connections or stray uninsulated wires exposed.
2. Place the junction box cover in place. Replace the two
screws removed earlier and tighten securely.
3. Replace the Zoneline front cabinet.
2

Advertisement

loading

This manual is also suitable for:

Rak4207Rak4307