Tools Required For Installation - Netafim SANDSTORM Installation Manual

Metal single/double chamber media filter
Hide thumbs Also See for SANDSTORM:
Table of Contents

Advertisement

INTRODUCTION
Backwash pipe
A pipe is necessary to take the backwash water from the backwash manifold back to the water source
(comply with your local regulations) or to the closest drainage ditch.
In order not to limit backwash flow rate:
The backwash pipe should be no longer than 20 m (65 ft).
The pipe diameter should never be smaller than the backwash manifold diameter.
If the backwash pipe length is 33 ft or less, it should be of the same diameter as the backwash manifold.
If the backwash pipe is longer than 33 ft, its diameter should be larger than the backwash manifold.
The pipe should not ascend above the elevation of the flushing manifold outlet.

Tools required for installation

No special tools are needed. A standard full installer toolkit is adequate.
To connect the control stand to the concrete slab, an electric hammering drill and a concrete drill bit.
To connect grooved couplings, the following wrenches are required:
Grooved coupling size Bolt and nut size
(inches)
2
3
4
6
8
10
6 | SANDSTORM
SINGLE/DOUBLE CHAMBER INSTALLATION MANUAL
((mm
(mm)
50
M10
80
M12
100
M12
150
M16
200
M20
250
M22
Wrench size
((mm
17
19
19
24
30
34

Advertisement

Table of Contents
loading

Table of Contents