Page 2
Arkal Spin-Klin 3” Battery – User Manual This Arkal 3” Spin Klin battery is an automatic self-cleaning filter designed for non-hazardous liquids only and within the pressure and temperature framework described in the specifications table 3” Spin-Klin Battery 2016 Page 2 of 13...
Operation During the filtration stage, water flows through the INLET manifold and is distributed through the 3” x 2” back-flush valves into the Spin Klin filters. The water then passes through the filter elements to the outlet manifold for consumer use.
Page 4
Spin Klin Technology - Spin Klin Spine General: The Spin Klin discs are stacked on the Spin Klin spine. The discs are color-coded by micron size, and are assembled according to your water filtration requirements. The spine assembly has a spring compression unit and an internal piston which are used to alternately compress and release the discs during filtration and back-flush cycles.
System Installation and Startup Technical Data Maximum Pressure 145 psi 10 bar at (25⁰ C) Minimum Pressure 38 psi 2.8 bar ³/h 20 m Back-flush Flow Rate per unit 88 gpm Maximum Temperature 158⁰F 70⁰C 4-11 4-11 3” Spin Klin Battery with Bermad Valves REF.
Page 6
Control Refer to the controller’s manufacturer user manual before installing the controller. Make sure that the voltage of both the solenoid unit and controller are correct. Set the manual operation button to automatic. Check that the ∆P hydraulic switch HIGH and LOW pressure lines are correctly connected to the appropriate ports. ...
Page 7
Spin Klin – System Maintenance Monthly Maintenance Check inlet /outlet pressures: In case the pressure differential is above 5 m / 7 PSI. Activate automatic back-flush of the Spin Klin filter battery. If the pressure differential remains high check for possible failures. Check for leakages from the drain manifold: In case there is a leakage of water during the filtration stage, check for possible failure at the back-flush valve seals.
Page 8
Seasonal Maintenance – Cleaning the Discs When manual cleaning of the discs is required, please follow the steps described below: Make sure that system is not under pressure! Release the clamp and remove the cover (Figures 1, 2) Figure 1 Figure 2 Unscrew the butterfly-nut on the filtration element (Figure 3) Remove the tightening cylinder (Figure 4)
Page 9
Cleaning Recommendations for Clogged Filtration Discs Water-formed deposits may cause clogging of the filter discs. The formation of these deposits depends on the quality of the filtered water and environmental conditions like temperature, pH, light, duration of filtration and more. Common water-formed deposits are: ...
Page 10
Cleaning Organic and Biological Deposits Open the filter and remove dirty discs. Attention – Never open the filter before the pressure has been released. Arrange the discs loosely on the plastic rope Prepare a 5% Sodium Hypochlorite solution: 1.
Page 11
Cleaning Complex Deposits If the composition of the deposit is not known, perform the following test: Take 5 discs for the test. Soak 2 discs in a 5% Sodium Hypochlorite Solution. Preparation of the solution: Pour 1 cup of water into a small container, then add 1 cup of Sodium Hypochlorite (10% NaOCl) ...
Page 12
Identifying Malfunctions in the 3” Spin Klin system No Back-flush Operation Important note: Command filter exists only in pressurized air controlled systems 3” Spin-Klin Battery 2016 Page 12 of 13...
Page 13
Continuous or Non-stop Back-flushing 3” Spin-Klin Battery 2016 Page 13 of 13...