Tools Required For Maintenance And Troubleshooting; Flange Connection - Netafim SANDSTORM User Manual

Metal single-/double-chamber media filter
Hide thumbs Also See for SANDSTORM:
Table of Contents

Advertisement

INTRODUCTION
Handling sodium hypochlorite (NaClO) or hydrogen peroxide (H
WARNING
Sodium hypochlorite (NaClO) and hydrogen peroxide (H
chemicals. All application regulations and safety rules must be observed. Store and handle them
according to safety regulations.
Before handling sodium hypochlorite (NaClO) or hydrogen peroxide (H
specific safety, health protection and first aid information and instructions. Be sure you have all
required first aid at the site, as instructed.
Concentrated liquid sodium hypochlorite (NaClO) or hydrogen peroxide (H
metal (especially threads that are exposed to water). Be careful when applying them and avoid the
spillage of any of the liquid onto exposed metal parts. Should any of the liquid come into contact
with metal parts, immediately wash thoroughly with fresh water.

Tools required for maintenance and troubleshooting

No special tools are needed. A standard toolkit is adequate.
To connect grooved couplings: The following wrenches are required:
Grooved coupling size Bolt and nut size
inch
2
3
4
6
8
10
To connect flanges: The following wrenches are required:
Flange size Bolt and nut size Wrench size
up to 8"
10" to 14"

Flange connection

In most cases, the filtration system manifolds are connected to the main line with flanges.
ATTENTION
When connecting flange pipe connectors, do not forget to place the rubber gasket in place.
(mm)
mm
50
M10
80
M12
100
M12
150
M16
200
M20
250
M22
5/8"
15/16"
7/8"
1.1/8"
Wrench size
(mm)
17
19
19
24
30
34
SINGLE-/DOUBLE-CHAMBER USER MANUAL 5
SANDSTORM
O
)
2
2
O
) are dangerous toxic and corrosive
2
2
O
), carefully read all the
2
2
O
) can damage exposed
2
2

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents