Note: The safety distance between the hotplate and the cupboard above the hotplate
should be at least 760mm.
A(mm)
760
Warning: Ensure adequate ventilation
Make sure the induction cooktop is well ventilated and that the air inlet and outlet are not
blocked. In order to avoid accidental touch with the overheating bottom of the cooktop or
getting an unexpected electric shock during working, it is necessary to put a wooden insert,
fixed by screws, at a minimum distance of 50mm from the bottom of the cooktop. Follow the
requirements below.
There are ventilation holes around the outside of the cooktop. You must ensure these
holes are not blocked by the worktop when you put the cooktop into position.
Be aware that the glue that joins the plastic or wooden material to the furniture
must resist to temperature not below 150°C, to avoid failure of the adhesive.
The rear wall, adjacent and surrounding surfaces must therefore be able to
withstand a temperature of 90°C.
B(mm)
C(mm)
50 (min)
20 (min)
D
Air intake
7
E
Air exit 5mm