Installation and operating instructions
QX³ series
AC cable requirements:
Item
A
B
C
D
Ensure the PE core is 5mm longer than the L and N cores!
AC mains connection
QX³4000-8000:
Pos
Meaning
A
L1
L2
B
C
L3
D
N
E
PE
NOTE
Q3 ENERGIE e recommends the use of flexible cable for installation.
_____________________________________________________________________________________________
Q3 ENERGIE Installation and operating instructions QX³ series
Version 1.0, Stand 27.04.2015
Meaning
Cable cross section
Cable diameter
Stripping the sheath
Stripping length
Value range
1,5 ... 4 mm² (QX³4000-8000)
4 ... 10 mm² (QX³10000-18000) with wire-end
ferrule.
Recommendation: use flexible cable to make
installation easier
QX³4000-8000
9 – 17mm
QX³10000-18000
VC-K-KV-PG21(14-18 mm)
VC-K-KV-PG21(17-20,5 mm)
Scope of delivery includes:
VC-K-KV-PG21(14-18 mm)
QX³10000-18000
approx. 40mm
QX³4000-8000
approx. 80mm
approx. 12mm
A B C D E
36/109