6. If the socket is not being used for a shelf light, the cap must be plugged into socket for entire light
system to operate.
7. Plug in shelf light by aligning the male pins on the appropriate shelf light cord plugs with the female
light sockets and push together. IMPORTANT: Do not roll plug during insertion.
8. Hang one end of the shelf support on to the rear notch of one shelf bracket and then on the rear notch of
the shelf bracket on the opposite side.
9. Place supplied shelving onto shelf supports as outlined in the appropriate "Shelf Installation" section of
this manual.
10. Removal of shelving is performed by following steps in reverse order.
11. The shelf standards are removable from case by removing the (2) shelf standard retaining screws
holding them to the inside wall of case.
Solid Shelf Installation
SHELF LIGHT CORD
RETAINER CLIP
SHELF LIGHT ASSEMBLY
1. Install shelf brackets & shelf supports as described in Shelf Bracket & Supports Installation Section of
this manual.
2. Place the front of metal shelf onto front shelf light. (On front shelf support for models without shelf
lights). The tab on end of shelf bracket must go through slot in front of shelf.
3. Place the back of shelf over the back of the rear shelf support.
RIGHT
SHELF STANDARD
RETAINING SCREW
SHELF BRACKET
TAB
WRONG
SLOT
REAR SHELF SUPPORT
- 11 -
REAR SHELF SUPPORT
SHELF LIGHT ASSEMBLY
SHELF STANDARD