Noise Level: Measure with a level meter (with a JIS-C fi lter):
[OUTPUT L/MONO] ---------> -90 dBu or less (10 kohm load)
[OUTPUT R] -------------------> -90 dBu or less (10 kohm load)
[ASSIGNABLE OUTPUT L] ----> -90 dBu or less (10 kohm load)
[ASSIGNABLE OUTPUT R] ----> -90 dBu or less (10 kohm load)
[PHONES (L)] -----------------> -90 dBu or less (33 ohm load)
[PHONES (R)] -----------------> -90 dBu or less (33 ohm load)
10 minutes or after the power is turned on, the voltage and
current with no option or jack is connected in the above
conditions should be as in the following table:
MOTIF XS6, XS7
Power unit connector pin
CN2–1, 2 Pin GND(3,4 Pin )
CN2–5 Pin
GND(6,7 Pin)
CN2–8 Pin
GND(8 Pin)
MOTIF XS8
Power unit connector pin
CN2–1, 2 Pin GND(3,4 Pin )
CN2–5 Pin
GND(6,7 Pin)
CN2–8 Pin
GND(8 Pin)
H. Default setting
Default setting of each controller of the unit is as follows.
VOLUME [1]–[8]:
Knob [1]–[8]:
[MASTER VOLUME]:
PITCH BEND Wheel:
MODULATION Wheel:
[A/D GAIN] VR:
[CONTRAST] VR:
[POWER ON/OFF] Switch:
Voltage
Current
+5 V ± 0.3 V
2000 ± 50 mA
+12 V ± 0.6 V
190 ± 10 mA
-12 V ± 0.6 V
40 ± 10 mA
Voltage
Current
+5 V ± 0.3 V
2400 ± 50 mA
+12 V ± 0.6 V
190 ± 10 mA
-12 V ± 0.6 V
40 ± 10 mA
Minimum
Middle
Minimum
Middle
Minimum
Minimum
Close to middle position and
adjusted such that LCD can be
seen easily
OFF
MOTIF XS6/MOTIF XS7/MOTIF XS8
137