Controllers for top-class blast chillers, in split version that can be built into the unit, with 5- or 7-inch colour tft touch-screen graphic display in either vertical or horizontal format (84 pages)
Controller for “top-class” blast chillers, with colour touch-screen tft graphic display, in split version and which can be integrated into the unit (94 pages)
Controllers for single-circuit chillers (46 pages)
Summary of Contents for Evco Vcolor 338
Page 1
EVCO S.p.A. Vcolor 338 | Installer manual ver. 3.0 | Code 144VC338E304 Vcolor 338 Controller for "top-class" electric ovens for gastronomy and pastry, with 5 or 7 inch TFT graphic display colour touch-screen, in split version that can be integrated into the unit.
Page 2
EVCO S.p.A. Vcolor 338 | Installer manual ver. 3.0 | Code 144VC338E304 Important Read this document thoroughly before installation and before use of the device and follow all recommendations; keep this document with the device for future consultation. Only use the device in the way described in this document; do not use the same as a safety device.
EVCO S.p.A. Vcolor 338 | Installer manual ver. 3.0 | Code 144VC338E304 OTHER FUNCTIONS ..........40 Indice 13.1 Display of the alarms status ........40 INTRODUCTION ............ 4 13.2 Display of the process variables value and of the Introduction ............4 machine status ............40 Summary table of the models available, the main 13.3...
Vcolor 338 | Installer manual ver. 3.0 | Code 144VC338E304 INTRODUCTION Introduction Vcolor 338 is a range of stylish controllers for electric “top- class” gastronomy and pastry ovens (also rack type). It is available in split version and the user interface can be mechanically integrated in the unit, resulting in an optimal aesthetic outcome;...
EVCO S.p.A. Vcolor 338 | Installer manual ver. 3.0 | Code 144VC338E304 Summary table of the models available, the main features and the purchase codes The following table illustrates the models available. Models available Vcolor 338 The following table illustrates the main features of the device.
Page 6
EVCO S.p.A. Vcolor 338 | Installer manual ver. 3.0 | Code 144VC338E304 Configurable (fan right rotation default) (1) Configurable (fan speed default) (1) Rack rotation Configurable (cleaning water valve by default) (2) Configurable (liquid detergent injection by default) (2) Configurable (cleaning liquids discharge by default) (2)
Page 7
EVCO S.p.A. Vcolor 338 | Installer manual ver. 3.0 | Code 144VC338E304 The following table illustrates the purchase codes. Vcolor 338M (kit with control module + 5” user interface) EVCMC33DJ2E for J/K thermocouples EVCMC33DC2E Pt 100 2 wires Vcolor 338L (kit with control module + 7” user interface)
EVCO S.p.A. Vcolor 338 | Installer manual ver. 3.0 | Code 144VC338E304 DIMENSIONS AND INSTALLATION User interface dimensions of Vcolor 338M The following drawing illustrates the 5-inch user interface dimensions; these are expressed in mm (in). User interface dimensions of Vcolor 338L The following drawing illustrates the 7-inch user interface dimensions;...
EVCO S.p.A. Vcolor 338 | Installer manual ver. 3.0 | Code 144VC338E304 Installation of user interface The following drawing illustrates the installation of the device user interface. This is to be installed on the back of the panel, with studs and allows flush mounting.
EVCO S.p.A. Vcolor 338 | Installer manual ver. 3.0 | Code 144VC338E304 Control module dimensions and installation The following drawing illustrates the device's control module dimensions; these are expressed in mm (in). The control module is to be installed on a flat surface, with spacers.
EVCO S.p.A. Vcolor 338 | Installer manual ver. 3.0 | Code 144VC338E304 ELECTRIC CONNECTION Electric connection of Vcolor 338M The following drawing illustrates the electric connection of the devices with a 5-inch user interface. For further information on ventilation management please refer to the following drawings.
EVCO S.p.A. Vcolor 338 | Installer manual ver. 3.0 | Code 144VC338E304 Electric connection of Vcolor 338L The following drawing illustrates the electric connection of the devices with a 7-inch user interface. For further information on ventilation management please refer to the following drawings.
Page 15
EVCO S.p.A. Vcolor 338 | Installer manual ver. 3.0 | Code 144VC338E304 Management of the ventilation in "on/off" mode and with single speed (parameter F0 = 0). Management of the ventilation in "on/off" mode and with single speed and inversion of the fan rotation direction (parameter F0 = 1).
Page 16
(parameter F0 = 3). The RS-485 MODBUS port is the communication port with the following EVCO products: Parameters Manager set-up software system The USB communication port that allows the upload and download of the device settings, through a common USB pen drive.
EVCO S.p.A. Vcolor 338 | Installer manual ver. 3.0 | Code 144VC338E304 DESCRIPTION Description of the user interface The following drawing illustrates the layout of the device user interface front panel. The following table illustrates the meaning of the front parts of the device user interface.
Page 19
EVCO S.p.A. Vcolor 338 | Installer manual ver. 3.0 | Code 144VC338E304 The following drawing illustrates the layout of the device user interface rear panel. The following table illustrates the meaning of the rear parts of the device user interface.
EVCO S.p.A. Vcolor 338 | Installer manual ver. 3.0 | Code 144VC338E304 Description of the control module The following drawing illustrates the layout of the device's control module. The following table illustrates the meaning of the device control module parts.
Page 21
EVCO S.p.A. Vcolor 338 | Installer manual ver. 3.0 | Code 144VC338E304 digital outputs K10... K13 digital output K9 digital outputs K6... K8 digital outputs K3... K5 high voltage digital inputs For further information, see the next chapters. page 21 of 68...
EVCO S.p.A. Vcolor 338 | Installer manual ver. 3.0 | Code 144VC338E304 COMMISSIONING Commissioning Operate as indicated: Install the device using the methods illustrated in chapter 2 “DIMENSIONS AND INSTALLATION”, following all warnings given in paragraph 2.4 “Installation warnings”. Connect the device electrically using the methods illustrated in chapter 3 “ELECTRIC CONNECTION”, following all warnings given in paragraph 3.3 “Warnings for the electric connection”, without connecting the power supply and the mains electricity.
Page 23
EVCO S.p.A. Vcolor 338 | Installer manual ver. 3.0 | Code 144VC338E304 Enables rotor Cleaning type disabled with liquid detergent, no recycling with tablet detergent and recycling Successively, check that the remaining settings are appropriate; see paragraph 16.3 “List of configuration parameters”...
EVCO S.p.A. Vcolor 338 | Installer manual ver. 3.0 | Code 144VC338E304 MANAGEMENT OF UTILITIES The air vent is opened automatically on conclusion of each Preliminary notes phase of a cooking cycle. This paragraph illustrates the activity of the utilities during To set the duration of the automatic air vent opening, see the normal operation.
EVCO S.p.A. Vcolor 338 | Installer manual ver. 3.0 | Code 144VC338E304 At the end of the w2 time, the resistors, ventilation, water Cooking fumes reduction solenoid valve and, after a w16 delay the water drain pump The cooking fumes reduction is active until the temperature will be turned off.
Page 26
EVCO S.p.A. Vcolor 338 | Installer manual ver. 3.0 | Code 144VC338E304 Important: with the w9=0 setting the "rinse aid" phase MEDIUM cleaning is bypassed entirely. HARD cleaning Phase 4 - Rinse: The rinse phase starts at the end of the Rinse aid cycle.
Page 27
EVCO S.p.A. Vcolor 338 | Installer manual ver. 3.0 | Code 144VC338E304 allow the recirculation pump to collect the water needed for the maximum water drain set point (parameter w19), the the various cleaning phases. controller will activate the Mains Water Injection output to Ventilation remains active for the whole duration of the phase, allow the condenser temperature to drop.
EVCO S.p.A. Vcolor 338 | Installer manual ver. 3.0 | Code 144VC338E304 6.10 User interface variant for ROTOR fase 1/3 C OTTURA 6min ovens management The ROTOR management controller differs from a COMBI one due to the additional presence of: rack rotation motor control relay 1 7 5 °...
EVCO S.p.A. Vcolor 338 | Installer manual ver. 3.0 | Code 144VC338E304 USER INTERFACE Switching the device on/off Operate as follows to switch the device on: Touch Operate as follows to switch the device off: Make sure no procedures are in progress.
EVCO S.p.A. Vcolor 338 | Installer manual ver. 3.0 | Code 144VC338E304 COOKING CYCLE Preliminary notes Every cooking cycle is preceded by preheating (on condition that Delta T cooking has not been set; the work set-point is relative to the work set-point during the first phase of the cooking cycle, i.e.
EVCO S.p.A. Vcolor 338 | Installer manual ver. 3.0 | Code 144VC338E304 Setting the cooking cycle Operate as follows to set the cooking type: Ensure that the device is switched on and that no other procedure is in progress. m a n u a l Touch the “manual”...
Page 32
EVCO S.p.A. Vcolor 338 | Installer manual ver. 3.0 | Code 144VC338E304 To select/scroll the cooking cycle phases, proceed as follows: Touch the reference bar F A S E 1 Operate as follows to add a phase to the cooking cycle: Touch the "add phase"...
EVCO S.p.A. Vcolor 338 | Installer manual ver. 3.0 | Code 144VC338E304 Starting the cooking cycle Once the cooking cycle has been launched, preheating will start. Opening and closing the door or pressing on the status bar causes the machine to start the first phase of the cooking cycle.
EVCO S.p.A. Vcolor 338 | Installer manual ver. 3.0 | Code 144VC338E304 “MY COOKBOOK” FUNCTION Preliminary notes The “MY COOKBOOK" function allows to memorise the settings of a cooking cycle in a recipe; when starting up the recipe, the device will function with the memorised settings.
EVCO S.p.A. Vcolor 338 | Installer manual ver. 3.0 | Code 144VC338E304 Starting a recipe “SPECIAL CYCLES” FUNCTION Operate as follows to start a recipe: 10.1 Preliminary notes Ensure that the device is switched on and that no The “Special cycles” function allows to use the work cycles other procedure is in progress.
EVCO S.p.A. Vcolor 338 | Installer manual ver. 3.0 | Code 144VC338E304 The following table illustrates the factory settings of the timed 10.2 Starting a special cycle proofing cycle. Operate as follows to start a special cycle: MINIMUM... Ensure that the device is switched on and that no...
EVCO S.p.A. Vcolor 338 | Installer manual ver. 3.0 | Code 144VC338E304 “FAVOURITE CYCLES” FUNCTION 11.1 Preliminary notes The “Favourite cycles” function allows to start one of the last 10 work cycles performed. One of the following types of work cycle can be started: cooking cycles set with the procedure illustrated in the paragraph 8.2 “Setting the cooking cycle”...
EVCO S.p.A. Vcolor 338 | Installer manual ver. 3.0 | Code 144VC338E304 "WEEKLY PROGRAMMED SWITCH-ON" FUNCTION 12.1 Preliminary notes The “Weekly programmed switch-on” function allows to program up to a maximum of 9 weekly switch-ons of the device and simultaneously start a recipe; see chapter 9 ““MY COOKBOOK”...
Page 39
EVCO S.p.A. Vcolor 338 | Installer manual ver. 3.0 | Code 144VC338E304 12.3 Enabling "Weekly programmed switch-on" function Operate as follows to access the procedure: Ensure that at least one switch-on is set, that the device is on and that no other procedure is in progress.
EVCO S.p.A. Vcolor 338 | Installer manual ver. 3.0 | Code 144VC338E304 OTHER FUNCTIONS 13.1 Display of the alarms status Operate as follows to access the procedure: Ensure that the device is switched on and that no other procedure is in progress.
EVCO S.p.A. Vcolor 338 | Installer manual ver. 3 | Installer manual ver. 3.0 | Code 144VC338E304 BOILER EXPANSION 14.1 Activation of the expansion pansion To enable the boiler expansion EVCLE305XXE EVCLE305XXE, it will be necessary to respect the following conditions.
Page 42
EVCO S.p.A. Vcolor 338 | Installer manual ver. 3 | Installer manual ver. 3.0 | Code 144VC338E304 In the BOILER menu, it will be possible to select the function In the BOILER menu, it will be possible to select the function RINSE...
EVCO S.p.A. Vcolor 338 | Installer manual ver. 3.0 | Code 144VC338E304 If the drain fails, the alarm “BOILER DRAIN” will be activated and it will be possible to reset it from key. If the maximum required level is not reached within the expected time (parameter t28), the alarm “MAX BOILER WATER LEV” will be activated and it will be possible to reset it from key.
EVCO S.p.A. Vcolor 338 | Installer manual ver. 3.0 | Code 144VC338E304 15.3 Application scheme The burner module EVCLE302XXE interacts with electronic ignition control boards for atmospheric burners such as "Honeywell 4565"series (and similar) and with variable speed centrifugal fans with PWM control signal+ feedback (HALL sensor).
EVCO S.p.A. Vcolor 338 | Installer manual ver. 3.0 | Code 144VC338E304 15.4 Operation During the heating phase, the controller will activate the relevant room or boiler heating outputs, as well as the relevant burner, whose heating power is managed proportionally to the work set point trough the centrifugal fan speed control.
EVCO S.p.A. Vcolor 338 | Installer manual ver. 3.0 | Code 144VC338E304 CONFIGURATION 16.1 Setting the time, date and day of the week Operate as follows to access the procedure: Ensure that the device is switched on and that no other procedure is in progress.
EVCO S.p.A. Vcolor 338 | Installer manual ver. 3.0 | Code 144VC338E304 16.2 Setting configuration parameters Operate as follows to access the procedure: Ensure that the device is switched on and that no other procedure is in progress. Touch Touch “SERVICE”.
EVCO S.p.A. Vcolor 338 | Installer manual ver. 3.0 | Code 144VC338E304 16.3 List of configuration parameters The following table illustrates the meaning of the device configuration parameters. PARAM. MIN. MAX. U.M. DEF. ANALOGUE INPUTS probe type thermocouple J (only in the J/K versions)
Page 49
EVCO S.p.A. Vcolor 338 | Installer manual ver. 3.0 | Code 144VC338E304 minimum delta T set-point (referring to the temperature detected by °C/°F (2) the needle probe) maximum delta T set-point (referring to the temperature detected °C/°F (2) by the needle probe) delta T set-point for factory setting (referring to the temperature °C/°F (2)
Page 50
EVCO S.p.A. Vcolor 338 | Installer manual ver. 3.0 | Code 144VC338E304 temperature above which the display of the temperature detected by the environment probe is locked (relative to the work set-point, i.e. °C/°F (2) “work set-point - c4”) function absent PARAM.
Page 51
EVCO S.p.A. Vcolor 338 | Installer manual ver. 3.0 | Code 144VC338E304 cycle time for injection of the steam generated in direct mode duration of the injection of the steam generated in direct mode corresponding to the maximum humidification injection delay of the steam generated in direct mode from start of a...
Page 52
EVCO S.p.A. Vcolor 338 | Installer manual ver. 3.0 | Code 144VC338E304 enabling of the restriction between the injection of the steam generated with external humidifier and the output for temperature regulation. - - - YES - if the output is off when the steam is injected, the...
Page 54
EVCO S.p.A. Vcolor 338 | Installer manual ver. 3.0 | Code 144VC338E304 type of electric absorption input contact - - - normally open (input active with closed contact) normally closed (input active with open contact) PARAM. MIN. MAX. U.M. DEF.
Page 55
EVCO S.p.A. Vcolor 338 | Installer manual ver. 3.0 | Code 144VC338E304 door action on rotor: the door opening stops the rotation When the door is closed afterwards, - - - the motor remains still it restarts as before the interruption...
Page 56
EVCO S.p.A. Vcolor 338 | Installer manual ver. 3.0 | Code 144VC338E304 °C/°F (2) working set point for the drying phase drying phase duration water discharge pump activation delay cleaning type 0 = disabled 1 = with liquid detergent, no recycling...
Page 57
EVCO S.p.A. Vcolor 338 | Installer manual ver. 3.0 | Code 144VC338E304 PARAM. MIN. MAX. U.M. DEF. BURNERS Reserved Lock screen 0 = disabled 1 = automatic Notes Properly set the parameters corresponding to the regulators after setting parameter P1...
EVCO S.p.A. Vcolor 338 | Installer manual ver. 3.0 | Code 144VC338E304 USE OF THE USB PORT 17.1 Preliminary information Through the USB port it is possible to make the following operations: upload and download of the settings contained in the recipes from the “MY COOKBOOK”...
EVCO S.p.A. Vcolor 338 | Installer manual ver. 3.0 | Code 144VC338E304 ALARMS 18.1 Alarms A buzzer is activated if an alarm occurs, the display shows the icon and an alarm code. Touch the display in the centre to silence the buzzer and restore normal display.
Page 60
EVCO S.p.A. Vcolor 338 | Installer manual ver. 3.0 | Code 144VC338E304 user interface-control module communication alarm solutions: No connection check user interface-control module connection ALARM main consequences: if the alarm occurs when the device is on, a cooking cycle cannot be started...
Page 61
EVCO S.p.A. Vcolor 338 | Installer manual ver. 3.0 | Code 144VC338E304 minimum boiler water level alarm solutions: Minimum boiler check boiler input; see parameter t27 water level ALARM main consequences: the boiler temperature regulation output will be deactivated cooking fumes probe alarm...
EVCO S.p.A. Vcolor 338 | Installer manual ver. 3.0 | Code 144VC338E304 ACCESSORIES 19.1 Optoisolated RS-485/USB serial interface The interface can be used to connect the device to the Parameters Manager set-up software system. 19.2 USB cap for panel installation The cap can be used to make the device USB communication port more accessible.
EVCO S.p.A. Vcolor 338 | Installer manual ver. 3.0 | Code 144VC338E304 TECHNICAL DATA 20.1 Technical data Purpose of the command device: operating command device. Construction of the command device: built-in electronic device. user interface user interface Case: black self-extinguishing.
Page 64
EVCO S.p.A. Vcolor 338 | Installer manual ver. 3.0 | Code 144VC338E304 12 VAC (±15%), 50 / 60 Hz (±3 Hz), supplied from the control module. 20 VA max. Rated impulse voltage: 4 KV. Overvoltage category: III. Class and structure of software: incorporated.
Page 65
EVCO S.p.A. Vcolor 338 | Installer manual ver. 3.0 | Code 144VC338E304 digital inputs for potential-free contact Power supply: none. Protection: none. digital inputs for high voltage contact Power supply: 230 VAC. Protection: none. 1 0-10 V output for fan management (in this case, an external speed regulator Analogue outputs: must be used).
Page 66
EVCO S.p.A. Vcolor 338 | Installer manual ver. 3.0 | Code 144VC338E304 2 ports: Communication port: 1x RS-485 MODBUS port 1x USB port. Signal buzzer and alarm: integrated. page 66 of 68...
Page 67
EVCO S.p.A. Vcolor 338 | Installer manual ver. 3.0 | Code 144VC338E304 Vcolor 338 Controller for "top-class" electric ovens for gastronomy and confectionery, with 7 inch TFT graphic display colour touch- screen, in split version and can be integrated into the unit.
Need help?
Do you have a question about the Vcolor 338 and is the answer not in the manual?
Questions and answers