INSTALLER: Leave this manual with party responsible for use and operation.
OWNER: Retain this manual for future reference.
SANTA FE PELLET INSERT
APPLIANCE
MODEL:
SANTAFEI-C
CAUTION
Check building codes prior to installation.
Installation MUST comply with local, regional, state
and national codes and regulations.
Consult local building, fire officials or authorities
having jurisdiction about restrictions, installation
inspection, and permits.
Installation and service of this appliance should be performed by
qualified personnel. Hearth & Home Technologies recommends
HHT Factory Trained or NFI certified professionals.
1
Installation Manual
Installation & Appliance Set-Up
NOTICE: DO NOT DISCARD THIS MANUAL
R
If the information in these instructions is
not followed exactly, a fire could result
causing property damage, personal injury,
or death.
Do not store or use gasoline or other flammable
vapors and liquids in the vicinity of this or any
other appliance.
Do not over fire - If appliance or chimney connector
glows, you are over firing. Over firing will void
your warranty.
Comply with all minimum clearances to combustibles
as specified. Failure to comply may cause house fire.
HOT SURFACES!
Glass and other surfaces are hot during
operation AND cool down. Hot glass will
cause burns.
Do not touch glass until it is cooled
NEVER allow children to touch glass
Keep children away
CAREFULLY SUPERVISE children in same room
as fireplace.
Alert children and adults to hazards of high
temperatures
High temperatures may ignite clothing or other
flammable materials.
Keep clothing, furniture, draperies and other
flammable materials away.
Tested and approved for wood pellets only. Burning of
any other type of fuel voids your warranty.
NOTE: To obtain a French translation of this
manual, please contact your dealer or visit
www.quadrafire.com
REMARQUE : Pour obtenir une traduction française de
ce manuel, s'il vous plaît contacter votre
revendeur ou visitez
7019-801C
WARNING
WARNING
CAUTION
www.quadrafire.com
July 10, 2019

Advertisement

Table of Contents
loading

Summary of Contents for Hearth & Home Quadra-Fire SANTA FE SANTAFEI-C

  • Page 1 Installation Manual Installation & Appliance Set-Up INSTALLER: Leave this manual with party responsible for use and operation. OWNER: Retain this manual for future reference. NOTICE: DO NOT DISCARD THIS MANUAL WARNING If the information in these instructions is SANTA FE PELLET INSERT not followed exactly, a fire could result causing property damage, personal injury, APPLIANCE...
  • Page 2: Table Of Contents

    SANTA FE PELLET INSERT Safety Alert Key: • DANGER! Indicates a hazardous situation which, if not avoided will result in death or serious injury. • WARNING! Indicates a hazardous situation which, if not avoided could result in death or serious injury. •...
  • Page 3: Important Safety Information

    SANTA FE PELLET INSERT Important Safety Information A. Appliance Certification B. BTU & Efficiency Specifications Emissions Report #: 0061PM077E Model Santa Fe Pellet Insert (2020) EPA Certification #: 175-19 Laboratory OMNI Test Laboratories, Inc. EPA Certified Emissions: 1.1 grams per hour Report No.
  • Page 4: Glass Specifications

    SANTA FE PELLET INSERT I. California - Prop65 C. Glass Specifications This appliance is equipped with 5mm ceramic glass. WARNING Replace glass only with 5mm ceramic glass. Please contact your dealer for replacement glass. This product and the fuels used to operate this product (wood), and the products of combustion of such fuels, can expose you to D.
  • Page 5: Getting Started

    SANTA FE PELLET INSERT Install Guide Getting Started A. Design, Installation & Location Since pellet exhaust can contain ash, soot or sparks, you must consider the location of: Considerations • Windows 1. Appliance Location • Air Intakes • Air Conditioner NOTICE: Check building codes prior to installation.
  • Page 6: Thermostat Wall Control Location

    SANTA FE PELLET INSERT C. Tools And Supplies Needed WARNING Tools and building supplies normally required for installation, unless installing into an existing masonry fireplace: Fire Risk. Reciprocating Saw Damaged parts could impair safe operation. Channel Locks Do NOT install damaged, incomplete or Hammer substitute components.
  • Page 7: Install Checklist

    SANTA FE PELLET INSERT E. Install Checklist ATTENTION INSTALLER: Follow this Standard Work Checklist This standard work checklist is to be used by the installer in conjunction with, not instead of, the instructions contained in this installation manual. __________________________________________________________________________ Customer: ______________________________________________________________________ Date Installed: _______________________________________________________________________...
  • Page 8: Dimensions And Clearances

    SANTA FE PELLET INSERT Dimensions and Clearances A. Appliance Dimensions 28-7/8 in [732mm] 23-5/8 in [600mm] 8 in [203mm] 23 in [584mm] 12-3/4 in 11-1/8 in 25-3/8 in 9-5/8 in [325mm] [283mm] [644mm] [246mm] 17-7/8 in [453mm] 9-1/2 in [243mm] 8-5/8 in 12-3/4 in 21-1/2 in [546mm]...
  • Page 9: Clearance To Combustibles, Ul And Ulc

    SANTA FE PELLET INSERT B. Clearance To Combustibles, UL and ULC 25 in.** 25 in.** (635mm) (635mm) 32-7/8 in. (835mm) 15-1/4 in.* Be sure to follow vent manufacturers clearance to (387mm) combustibles. *If interior of chase will be drywalled, add the thickness to this measurement.
  • Page 10: Masonry Chimney And Fireplace Clearances

    SANTA FE PELLET INSERT C. Masonry Chimney and Fireplace D. Minimum Opening for Masonry & ZC Clearances Fireplaces TOP TRIM 26-3/4 in 20-3/4 in (679mm) (527mm) 29-3/4 in (1010mm) Figure 10.3 16 in HEARTH (406mm) EXTENSION Location Inches Millimeters Height 23-1/4 Figure 10.1 Front Width...
  • Page 11: Installation Into A Factory-Built Fireplace

    SANTA FE PELLET INSERT G. Installation into a Factory-Built Fireplace The following is only one example as there are many different models of factory-built fireplaces. The following modifications are permissible: Removal of damper or locked in open position NOTE: This example is for reference only. Any Removal of smoke shelf or baffle modifications must not compromise the Removal of ember catches...
  • Page 12: Installation Into A Masonry Fireplace

    SANTA FE PELLET INSERT H. Installation into a Masonry Fireplace I. Prefabricated Metal Chimney All modifications that can be made to a Factory Built The chimney can be new or existing, masonry Fireplace can be made to a Masonry Fireplace. or prefabricated and must meet the following minimum requirements: In addition DO NOT remove any brick or mortar from the...
  • Page 13: Vent Information

    SANTA FE PELLET INSERT Vent Information A. Venting Termination Minimum Requirements Electrical Service Inside Corner FIXED FIXED OPEN CLOSED CLOSED OPEN J or K Termination Cap Air Supply Inlet Gas Meter Restricted Area All minimum clearances are listed with an Outside Air Kit (OAK) installed, unless otherwise noted in table below. 12 in.
  • Page 14: Avoiding Smoke And Odors

    SANTA FE PELLET INSERT B. Avoiding Smoke and Odors Vent Configurations When installing a pellet appliance with a horizontal vent Negative Pressure, Shut-Down and Electrical Power configuration the frequency of power outages should Failure be considered: To reduce the probability of back-drafting or burn-back •...
  • Page 15: Negative Pressure

    SANTA FE PELLET INSERT E. Chimney and Exhaust Connection C. Negative Pressure NOTE: The appliance exhaust outlet is designed to WARNING accommodate 3 inch venting. Use of 4 inch venting requires the use of a 3-to-4 inch exhaust Risk of Asphyxiation! vent increaser in addition to any other venting Negative pressure can cause spillage of combustion components needed, sold separately.
  • Page 16: Equivalent Feet Of Pipe

    SANTA FE PELLET INSERT F. Equivalent Feet of Pipe WARNING The table below can help you calculate the equivalent feet of pipe which is a method used to determine pellet vent size (Figure 16.1). Vent surfaces get HOT, can cause burns if touched.
  • Page 17: Venting Systems

    SANTA FE PELLET INSERT Venting Systems A. Direct Connect with Outside Air B. Direct Connect without Outside Air NOTE: In Canada, only a full reline is allowed per ULC S628-93, ORD ULC C1482-M1990. NOTE: • Use metal plate around exhaust vent pipe and seal all edges with non- flammable insulation such as fiberglass, mineral wool...
  • Page 18: Full Reline With Outside Air - Horizontal

    SANTA FE PELLET INSERT C. Full Reline With Outside Air - Horizontal WARNING CAUTION Fire Risk. Never draw outside combustion air from: Inspection of Chimney: • Wall, floor or ceiling cavity • Masonry chimney must be in • Enclosed space such as an attic or garage good condition.
  • Page 19: Full Reline With Outside Air - Vertical

    SANTA FE PELLET INSERT D. Full Reline With Outside Air - Vertical NOTE: In Canada, only a full reline is allowed per ULC S628-93, ORD ULC C1482-M1990. NOTE: Check clearances carefully for this type of installation to ensure adequate room for outside NOTE: In Canada this fireplace insert must be installed air venting.
  • Page 20: Appliance Set-Up

    SANTA FE PELLET INSERT Appliance Set-Up A. Leveling System D. Outside Air Kit Instructions The leveling bolts are located at the rear of the appliance. 1. Measure distance from floor to air vent opening in To access the bolts, remove the front access panels. appliance and mark location on wall.
  • Page 21: Adjustable Hearth Support

    SANTA FE PELLET INSERT E. Adjustable Hearth Support EXPLODED VIEW OF SCISSORS Size: 9”d x 45”w, 2” to 10” Height Adjustment 1. The 10 screws on each set of scissors will already be loose when shipped (Figure 21.1). SCREWS ARE CIRCLED 2.
  • Page 22: Panel And Trim Set

    SANTA FE PELLET INSERT F. Panel and Trim Set 1. Lay panel top and legs face down on protective Open Hopper Lid for covering to prevent scratching. Easier Placement of 2. Attach the panel legs to the top panel using a Phillips Panel Set head screwdriver.
  • Page 23: Thermostat Installation

    SANTA FE PELLET INSERT G. Thermostat Installation The kit comes with a programmable wall thermostat and 25’ of thermostat wire. If you need to run more than 25’ make sure you use a continuous strand of 18 to 22 gauge thermostat wire.
  • Page 24: Optional Log Set Placement Instructions

    SANTA FE PELLET INSERT H. Optional Log Set Placement Instructions 2 Piece Log Set Installation 1. Open door to expose the firebox. 2. Install the left log first and then the right log (Figure 24.1). 3. Lean the logs against the cast iron brick in the back of the firebox.
  • Page 25: Mobile Home Installation

    SANTA FE PELLET INSERT Mobile Home Installation You must use a Quadra-Fire Outside Air Kit for CAUTION installation in a mobile home. 1. An outside air inlet must be provided for the combustion air and must remain clear of leaves, debris, THE STRUCTURAL INTEGRITY OF THE MOBILE ice and/or snow.
  • Page 26: Reference Materials

    SANTA FE PELLET INSERT Reference Materials A. Service & Maintenance List Date of Service Performed By Description of Service 7019-801C July 10, 2019...
  • Page 27 SANTA FE PELLET INSERT Date of Service Performed By Description of Service July 10, 2019 7019-801C...
  • Page 28 SANTA FE PELLET INSERT Date of Service Performed By Description of Service 7019-801C July 10, 2019...
  • Page 29 SANTA FE PELLET INSERT Date of Service Performed By Description of Service July 10, 2019 7019-801C...
  • Page 30: Accessory List

    at Depot ITEM DESCRIPTION COMMENTS PART NUMBER SANTA FE PELLET INSERT Hopper Switch Magnet Bracket SRV7019-217 Magnetic Switch SRV7000-375 B. Accessory List Magnet Round SRV7000-140 SANTAFEI-C Service Parts Plate, Ash Cleanout 7001-186 Wire Harness Hopper Switch SRV414-1220 Beginning Manufacturing Date: Apr 2019 Ending Manufacturing Date: Active IMPORTANT: THIS IS DATED INFORMATION .
  • Page 31 SANTA FE PELLET INSERT SANTAFEI-C Service Parts Beginning Manufacturing Date: Apr 2019 Ending Manufacturing Date: Active IMPORTANT: THIS IS DATED INFORMATION . Parts must be ordered from a dealer or Stocked Hearth and Home Technologies does not sell directly to consumers distributor.
  • Page 32 CONTACT INFORMATION Hearth & Home Technologies 352 Mountain House Road Halifax, PA 17032 Division of HNI INDUSTRIES Please contact your Quadra-Fire dealer with any questions or concerns. For the number of your nearest Quadra-Fire dealer log onto www.quadrafire.com CAUTION DO NOT DISCARD THIS MANUAL Read, understand and Leave this manual with •...

Table of Contents