Download Print this page

Henny Penny CW-216 Service Manual page 37

Display counter warmer
Hide thumbs Also See for CW-216:

Advertisement

1. Remove electrical power supplied to the cabinet.
lace the power switch in the off position, shut off the
power at the fuse or breaker box. Failure to do this
could result in electrical shock.
2. Remove control side end panel per paragraph 2-4.
3. Remove the wires from the switch.
th test instrument
check across the terminals of the switch with the switch
in the on position, then in the off position. With the switch
in the on position the circuit should be closed. With the
switch in the off position the circuit should be open. if the
switch checks defective replace by continuing with this
procedure.
4. Remove the nut from control panel side and remove
switch.
5. Install a new switch in reverse order.
6. Replace the end panel.
7. Turn on the power supply at the breaker box.
1. Remove electrical power supplied to the cabinet.
Place the power switch in the off position, shut off the
power at the fuse or breaker box. Failure to do this
could result in electrical shock.
2. Remove the control side end panel as per paragraph 2-4.
3. Remove the electrical wires from the switch. With test
instrument check across the terminals of the switch with
the switch in the on position, then in the off position.
the switch in the on position, the circuit should be closed.
e switch in the off position, the circuit should be
the switch checks defective, replace by continuing
with this procedure.