Download Print this page

Henny Penny CW-216 Service Manual page 28

Display counter warmer
Hide thumbs Also See for CW-216:

Advertisement

A. Reading Does
Thermometer bulb is not in
holding block.
Faulty thermometer.
Insert bulb in block.
Replace as per paragraph
5-15.
Temperature
B. Doors Are
Fogging.
Doors are not kept closed.
Product held too long.
ater temperature too low.
Radiant heat too low.
Radiant heat not working.
Light bulbs out.
oors left open too much
allowing doors to cool and
cause condensation.
Radiant heat not high enough.
Radiant heat not working.
Water temperature too high.
Keep doors closed when
possible.
Only hold product for recom-
mended times.
Check water heating system
as per paragraph 5-18.
Turn to higher setting.
Check radiant heat system as
per paragraph 5-19.
Replace as required, see
paragraph 5-3.
eep doors closed when
possible.
Turn to higher setting.
Check radiant heater as per
paragraph 5-19.
See recommended settings
and temperature.

Advertisement