Example 2:
Writing of non-permissible value 0 in parameter
Request: Master  frequency inverter
Byte
...
0
TCP/IP
Header
Header
> 40
7
6
Bytes
1
0
Error response: Frequency inverter  Master
Byte
...
0
TCP/IP
Header
Header
> 40
7
6
Bytes
1
1
Example 3:
Writing of parameter
Fixed frequency 3
cy inverter.
The fixed frequency is to be set to 44.50 Hz. Parameter
es. Thus the value to be sent is 4450 = 0x00001162.
Request: Master  frequency inverter
Byte
...
0
TCP/IP
Header
Header
> 40
7
6
Bytes
1
0
Response: Frequency inverter  Master
Byte
...
0
TCP/IP
Header
Header
> 40
7
6
Bytes
1
0
The response is the reflected signal of the request message.
12/13
Rated mech. power
1
2
3
NoB
SYS
DS
5...0
0
06
00
04
1
2
3
NoB
SYS
DS
5...0
0
06
00
04
482 (0x01E2) in dataset 9 (= RAM for dataset 4) of frequen-
1
2
3
NoB
SYS
DS
5...0
0
08
00
09
1
2
3
NoB
SYS
DS
5...0
0
08
00
09
Agile
VABus/TCP
376 (0x0178) in dataset 2.
4
5
6
7
P.-No.
data
LSB
MSB
uint/int data
LSB
MSB
78 01
00
00
4
5
6
7
P.-No.
data
LSB
MSB
uint/int data
LSB
MSB
78 01
01
00
482 has two decimal plac-
Fixed frequency 3
4
5
6
7
P.-No.
data
LSB
MSB
long data
LSB
E2 01
62
11
4
5
6
7
P.-No.
data
LSB
MSB
long data
LSB
E2 01
62
11
8
9
MSB
00
00
8
9
MSB
00
00