Danfoss ADAP-KOOL AK-CT 200A User Manual page 35

Controller tray for refrigeration appliance control with tev, refrigeration control systems
Table of Contents

Advertisement

Continued
Displacement of time on cutin of defrost at start-up
Drip off time
Delay for fan start after defrost
Fan start temperature
Fan cutin during defrost
0: Stopped
1: Running
2: Running during pump down and defrost
Defrost sensor: 0 =Stop on time, 1=S5, 2=S4, 3=S5 og S5B)
Pump down delay
Drain delay (used at hot gas defrost only)
Max. aggregate refrigeration time between two defrosts
Heat in drip tray. Time from defrosting stops to heating in the
drip tray is switched off
Number of permissible extended defrost cycles before an alarm
is issued
Rail heat during defrost cycle:
0=inactive, 1=continues as set, 2=100% on
Fan
Fan stop temperature (S5)
Pulse operation on fans: 0=No pulse operation, 1=At thermostat
cuts out only, 2= Only at thermostat cut outs during night
operation
Period time for fan pulsation (on-time + off-time)
On-time in % of period time
Max. permissible S4 temperature during defrost cycle. If the value
is exceeded, the fans will stop. (Setting = 15 = no function)
Electricity monitoring
Current measured electricity through relay 1 (DO1)
Same for relays 2 to 8
Fuse status for relay 1/Forced control of relay 1./ Reconnection
Same for relays 2 to 8
Electrical current value at which relay cuts out; 0 = not used
Recommended setting = measured consumption + 25%
Same for relays 2 to 8
Current measured voltage in phase L1
Current measured voltage in phase L2
Current measured voltage in phase L3
Alarm limit for low consumption on DO2
Alarm limit for low consumption on DO5
Alarm limit for low consumption on DO6
Alarm limit for low consumption on DO8
Parameters for refrigeration function
Period time for the pulse width period (PWM)
Max. opening degree at PWM
Min. opening degree at PWM
Expert setting. Windup at PWM
Expert setting. Kp at PWM
Expert setting. Tn at PWM
Miscellaneous
Delay of output signals after start-up
Input signal on DI1. Function:
0=not used. 1=status on DI1. 2=door function with alarm when
open. 3=door alarm when open. 4=defrost start (pulse-signal).
5=ext.main switch. 6=night operation 7=thermostat band
changeover (activate r21). 8=alarm function when closed.
9=alarm function when open. 10=case cleaning (pulse signal).
11=forced cooling at hot gas defrost, 12=night cover. . 13=not
used. 14=forced close. 15=appliance shutdown. 16=light.
17=extra light. 18=cancel defrost. 19=override light.
Network address
On/Off switch (Service Pin message)
IMPORTANT! o61 must be set prior to o04
(used at LON 485 only)
Access code 1 (all settings)
Used sensor type : 0=Pt1000, 1=Ptc1000,
AK-CT 450A
Code
d05
d06
d07
d08
d09
d10
d16
d17
d18
d20
d26
d27
F-
F04
F05
F06
F07
F22
L-
L11
L12-
L18
L21
L22-
L28
L31
L32-
L38
L51
L52
L53
L62
L65
L66
L68
n-
n63
n64
n65
n66
n67
n68
o-
o01
o02
o03
o04
o05
o06
User Guide RS8GR602 © Danfoss 2016-10
1
2 3
4
5
6 7
8
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
Min.
Max.
Fac.
0 min.
240 min.
0
0 min.
60 min.
0
0 min.
60 min.
0
-50 °C
0 °C
-5
0
2
1
0
3
0
0 min.
60 min.
0
0 min.
60 min.
0
0 hrs
48 hrs
0/OFF
0 min.
240 min.
30
1
10
1
0
2
2
-50°C
50°C
50
0
2
0
1 min.
30 min.
5
0 %
100 %
100
-15°C
15°C
15
Ampere
Ampere
0/off
1/on
1/on
0/off
1/on
1/on
0 /4A
16 A
16
0 /4A
16 A
16
V
V
V
0 A
10 A
1
0 A
10 A
1
0 A
10 A
0
0 A
10 A
1
30 sec.
900 sec.
300
10%
100%
100
0%
90%
0
0.2
1.0
1.0
0.5
10.0
4.0
60 sec
1800 sec
300
0 sec
600 sec
5
0
19
0
0
240
0
0/Off
1/On
0/Off
0
100
0
0/Pt
1/Ptc
0/Pt
Actual
35

Hide quick links:

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the ADAP-KOOL AK-CT 200A and is the answer not in the manual?

This manual is also suitable for:

Adap-kool ak-ct 450aAk-ct 200aAk-ct 550a

Table of Contents