Danfoss ADAP-KOOL AK-CT 200A User Manual page 34

Controller tray for refrigeration appliance control with tev, refrigeration control systems
Table of Contents

Advertisement

Menu
Function
Normal operation
Temperature (setpoint)
Thermostat
Differential
Max. limitation of setpoint setting
Min. limitation of setpoint setting
Adjustment of temperature indication
Temperature unit (°C/°F)
Correction of the signal from S4
Correction of the signal from S3 and S3B
Manual service, stop regulation, start regulation (-1, 0, 1)
Displacement of reference during night operation
Define thermostat function
1=ON/OFF, 2=Modulating
Definition and weighting, if applicable, of thermostat sensors -
S4% (100%=S4, 0%=S3)
Time between melt periods
Duration of melt periods
Temperature setting for thermostat band 2 . As differential use
r01
Correction of the signal from S6
Correction of the signal from S6B
Definition and weighting, if applicable, of thermostat sensors
when night cover is on. (100%=S4, 0%=S3)
Heat function
Neutral zone between refrigeration and heat function
Time delay at switch between refrigeration and heat function.
For setting = after 240 min. the heating function is deactivated
Product type: use settings listed in table.
Alarms
Delay for temperature alarm
Delay for door alarm
Delay for temperature alarm after defrost
High alarm limit for thermostat 1
Low alarm limit for thermostat 1
High alarm limit for thermostat 2
Low alarm limit for thermostat 2
High alarm limit for sensor S6 at thermostat 1
Low alarm limit for sensor S6 at thermostat 1
High alarm limit for sensor S6 at thermostat 2
Low alarm limit for sensor S6 at thermostat 2
S6 alarm time delay
With setting = 240 the S6 alarm will be omitted
Alarm time delay or signal on the DI1 input
Alarm time delay or signal on the DI2 input
Signal for alarm thermostat. S4% (100%=S4, 0%=S3)
Delay for S6 (product sensor alarm) after defrost
Delay for temperature alarm S3B
Compressor
Min. ON-time
Min. OFF-time
Time delay for cutin of comp.2
Defrost
Defrost method: 0=none, 1= EL, 2= Gas, 3=Brine, 4=Air
Defrost stop temperature
Interval between defrost starts
Max. defrost duration
34
Parameter
***
r-
***
***
***
A-
c-
d-
User Guide RS8GR602 © Danfoss 2016-10
El-diagram page 12 to 16
Code
1
2
3
4
5
6
- - -
1
1
1
1
1
1
r01
1
1
1
1
1
1
r02
1
1
1
1
1
1
r03
1
1
1
1
1
1
r04
1
1
1
1
1
1
r05
1
1
1
1
1
1
r09
1
1
1
1
1
1
r10
1
1
1
1
1
1
r12
1
1
1
1
1
1
r13
1
1
1
1
1
1
r14
1
1
1
1
1
1
r15
1
1
1
1
1
1
r16
1
1
1
1
1
1
r17
1
1
1
1
1
1
r21
1
1
1
1
1
1
r59
1
1
1
1
1
1
r60
1
1
1
1
r61
1
1
1
1
1
1
r62
1
1
1
1
1
1
r63
1
1
1
1
1
1
r89
1
1
1
1
1
1
A03
1
1
1
1
1
1
A04
1
1
1
1
1
1
A12
1
1
1
1
1
1
A13
1
1
1
1
1
1
A14
1
1
1
1
1
1
A20
1
1
1
1
1
1
A21
1
1
1
1
1
1
A22
1
1
1
1
1
1
A23
1
1
1
1
1
1
A24
1
1
1
1
1
1
A25
1
1
1
1
1
1
A26
1
1
1
1
1
1
A27
1
1
1
1
1
1
A28
1
1
1
1
1
1
A36
1
1
1
1
1
1
A52
1
1
1
1
1
1
A53
1
1
1
1
c01
1
1
1
1
1
1
c02
1
1
1
1
1
1
c05
d01
1
1
1
1
1
1
d02
1
1
1
1
1
1
d03
1
1
1
1
1
1
d04
1
1
1
1
1
1
Min.-
Max.-
value
value
7
8
1
1
-50°C
50°C
2
1
1
0.1 K
20 K
2
1
1
-49°C
50°C
50
1
1
-50°C
49°C
-50
1
1
-10
10
0
1
1
0/°C
1/F
0/°C
1
1
-10 K
10 K
0
1
1
-10 K
10 K
0
1
1
-1
1
0
1
1
-50 K
50 K
0
1
1
1
2
1
1
1
0 %
100 %
100
1
1
0 hrs
10 hrs
1
1
1
0 min.
30 min.
5
1
1
-50°C
50°C
2
1
1
-10 K
10 K
0
-10 K
10 K
0
1
1
0 %
100 %
100
1
1
0 K
50 K
5
1
1
0 min.
240 min.
240
1
1
0
5
0
1
1
0 min.
240 min.
30
1
1
0 min.
240 min.
60
1
1
0 min.
240 min.
90
1
1
-50°C
50°C
8
1
1
-50°C
50°C
-30
1
1
-50°C
50°C
8
1
1
-50°C
50°C
-30
1
1
-50°C
50°C
8
1
1
-50°C
50°C
-30
1
1
-50°C
50°C
8
1
1
-50°C
50°C
-30
1
1
0 min.
240 min.
240
1
1
0 min.
240 min.
30
1
1
0 min.
240 min.
30
1
1
0 %
100 %
100
1
1
0 min.
240 min.
90
0 min.
240 min.
90
1
0 min.
30 min.
0
1
0 min.
30 min.
0
1
0 sec
999 sec
5
1
1
0/No
4/Air
1/EL
1
1
0°C
50°C
6
1
1
0 hrs/Off
240 hrs
8
1
1
0 min.
360 min.
45
SW = 1.8x
Factory
Actual
setting
setting
AK-CT 450A

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Adap-kool ak-ct 450a

Table of Contents