Danfoss ADAP-KOOL AK-CT 200A User Manual page 28

Controller tray for refrigeration appliance control with tev, refrigeration control systems
Table of Contents

Advertisement

Fan pause while night blind rolls down
Here you can set the fan pause time, so the night blind can roll down unhindered
to the correct position.
Max. on time for light after manual DI activation
Delay time before light goes off again after light has been turn on manual due to
product stocking.
Service
Temperature measured with S5 sensor
Status on DI1 input. on/1=closed
Read the duration of the ongoing defrost or the duration of the last completed
defrost.
Temperature measured with S3 sensor
Status at the day-/night operation (night operation: on/off )
Temperature measured with S4 sensor
Thermostat temperature
Read the ongoing cutin time for the thermostat or the duration of the last
completed cutin
Read the valve's actual opening degree
Read the temperature at the S6 sensor
Status on DI2 input. on/1=closed
Air temperature. Weighted S3 + S4
Measured temperature for alarm thermostat
* Status on relay for cooling
Status on relay for fan
* Status on relay for defrost
Status on relay for railheat
* Status on relay for alarm
Status on relay for light
* Status on relay for hot gas valve
* Status on relay for compressor 2
* Temperature measured with S5B sensor
* Temperature measured with S3B sensor
* Temperature measured with S6B sensor
* Status on relay for hot gas
* Status on relay for heating element in drip tray
* Status on relay for night blinds
* Status on relay for defrost 2
* Readout of the actual rail heat effect in %
Readout of which thermostat used for regulation: 1= Thermostat 1,
2= Thermostat 2
Status on input DI3 (closed / open)
Readout of the actual cutin value for the thermostat
Readout of the actual cut out value for the thermostat
* Measured temperature for alarm thermostat for B section
* Air temperature. Weighted S3 + S4 temp. for B section
* Status of relay for light 2
* Status of relay for ECO fan
* Status of relay for defrost 3
Status of DI4 input. On=closed
Status of DI5 input. On=closed
Status of DI6 input. On=closed
Status of high-voltage input DI7, 230 V = 1 = closed
Status of high voltage input DI8, 230 V = 1 = closed
0-10 V output indicates EVR valve's degree of opening
28
User Guide RS8GR602 © Danfoss 2016-10
P65
BlindFanStop
P66
Light On Time
Case shutdown
Service
u09
S5 temp.
u10
DI1 status
u11
Defrost time
u12
S3 air temp
u13
Night Cond.
u16
S4 air temp
u17
Ther. air
u18
Ther runtime
u23
Valve OD %
u36
S6 temp
u37
DI2 status
u56
Display air
u57
Alarm air
u58
Comp1/LLSV
u59
Fan relay
u60
Def. relay
u61
Railh. relay
u62
Alarm relay
u63
Light relay
u64
SuctionValve
u67
Comp2 relay
u75
S5 temp. B
u76
S3 air temp B
u79
S6 temp. B
u80
Hotgas valve
u81
Drip tray
u82
Blinds relay
u83
Def. relay 2
u85
Rail DutyC %
u86
Ther. band
u87
DI3 status
u90
Cutin temp.
u91
Cutout temp.
U34
Alarm air B
U35
Display air B
U36
Extra light
U37
Fan Eco
U38
Def. relay 3
U39
DI4 status
U40
DI5 status
U41
DI6 status
U42
DI7 status
U43
DI8 status
U44
AO1 voltage
AK-CT 450A

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Adap-kool ak-ct 450a

Table of Contents