Continued
Input signal on DI5. Contact switch. See DI3 above
Input signal on DI6. Contact switch. See DI3 above
Input signal on DI7. High voltage signal. See DI3 above
Input signal on DI8. High voltage signal. See DI3 above
Max. opening time of night blind following manual override
with DI activation.
Erase all current controller settings on ID module.
Configuration of night blind relay. On= night blind used
Stop time for fan while night blind rolls down
Max. on time for light and night blind following manual
DI activation
Real time clock
Six start times for defrost.
Setting of hours.
0=OFF
Six start times for defrost.
Setting of minutes.
0=OFF
Clock - Setting of hours
Clock - Setting of minute
Clock - Setting of date
Clock - Setting of month
Clock - Setting of year
Service
Temperature measured with S5 sensor
Status on DI1 input. on/1=closed
Actual defrost time (minutes)
Temperature measured with S3 sensor
Status on night operation (on or off ) 1=on
Temperature measured with S4 sensor
Thermostat temperature
Run time of thermostat (cooling time) in minutes
Opening degree of EVR valve
Temperature measured with S6 sensor
(product temperature)
Status on DI2 input. on/1=closed
Air temperature . Weighted S3 and S4
Measured temperature for alarm thermostat
Status on relay for cooling
Status on relay for fan
Status on relay for defrost
Status on relay for rail heat
Status on relay for alarm
Status on relay for light
Status on relay for hot gas valve
Status on relay for compressor 2
Temperature measured with S5B sensor
Temperature measured with S3B sensor
Temperature measured with S6B sensor
Status on relay for hot gas valve / drain valve
Status on relay for heating element in drip tray
Status on relay for night blinds
Status on relay for defrost 2
Readout of the actual rail heat effect
1: Thermostat 1 operating, 2: Thermostat 2 operating
Status on DI3 input. on/1=closed
Readout of thermostats actual cut in value
Readout of thermostats actual cut out value
Measured temperature for alarm thermostat in section B
Air temperature in section B
Status of relay for light 2
AK-CT 450A
Code
P56
P57
P58
P59
P60
P61
P64
P65
P66
t-
t01 -
t06
t11 -
t16
t07
t08
t45
t46
t47
u-
u09
u10
u11
u12
u13
u16
u17
u18
**
u23
u36
u37
u56
u57
**
u58
**
u59
**
u60
**
u61
**
u62
**
u63
**
u64
**
u67
u75
u76
u79
**
u80
**
u81
**
u82
**
u83
u85
u86
u87
u90
u91
U34
U35
**
U36
User Guide RS8GR602 © Danfoss 2016-10
1
2 3
4
5
6 7
8
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
Min.
Max.
Fac.
0
19
0
0
19
0
0
19
0
0
19
0
0 min.
60 min.
5
0 / off
1 / on
0 / off
0 / off
1 / on
1 / on
0 sec
300 sec
60
0 min.
60 min.
30
0 hrs
23 hrs
0
0 min.
59 min.
0
0 hrs
23 hrs
0
0 min.
59 min.
0
1 day
31 day
1
1 mon.
12 mon.
1
0 year
99 year
0
Actual
37