Panasonic Minas-LIQI Series Technical Reference page 11

Ac servo amplifier
Table of Contents

Advertisement

Function number table
Signal
Invalid
Positive overtravel limit
Negative overtravel limit
Servo on
Alarm clear
(No setting)
Gain switch
Deviation counter clear
Command pulse inhibition
Torque limit switch
Damping switch 1
Damping switch 2
Command scaling switch
Command scaling switch 2
(No setting)
Forced alarm input
(No setting)
Precautions:
・Do not set any value other than set values specified in the table.。If it is set other than values specified in the
table,Err33.2 "IF input function number error 1 protection" or Err33.3 "IF input function number error 2 protection" will occur.
And the (No setting) in the table is set to protection function. Because input do not operate, please set it to invalid(00h).
・A function can not be assigned to more than one signal. If any function is assigned to more than one signal, Err33.0 "IF overlaps
allocation error 1 protection" and Err33.1 "IF overlaps allocation error 2 protection" will occur.
・Deviation Counter Clear (CL) can be assigned only to SI7 Input. If it is assigned to the other signals, Err33.6 "CL fitting error
protection" will occur.
・Command Pulse Inhibition (INH) can be assigned only to SI10 Input. If it is assigned to the others, Err33.7 "INH fitting error
protection" will occur.
・Control input pins set as invalid do not affect operations.
・Servo-on Input Signal (SRV-ON) must always be assigned. When it is not assigned, Servo-on cannot be activated
Code
Setting
a connect
-
00h
POT
01h
NOT
02h
SRV-ON
03h
A-CLR
04h
-
05h
GAIN
06h
CL
07h
INH
08h
TL-SEL
09h
VS-SEL1
0Ah
VS-SEL2
0Bh
DIV1
0Ch
DIV2
0Dh
-
0Eh~13h
E-STOP
14h
-
15h
Motor Business Unit, Appliances Company, Panasonic Corporation
№SR-ZSV00039 - 7 -
b connect
Not available
81h
82h
83h
Not available
85h
86h
Not available
88h
89h
8Ah
8Bh
8Ch
8Dh
8Eh~93h
94h
95h