WIRING

3 WIRING
Source logic
Main circuit terminal
Control circuit terminal
MCCB
3-phase AC
power supply
*2.To supply power to the
control circuit separately,
remove the jumper across R1/
L11 and S1/L21.
Control input signals (No voltage input allowed)
Forward
Terminal functions
rotation
vary with the input
terminal assignment
Reverse
rotation
(Pr. 178 to Pr. 189)
Start self-holding selection
High speed
Multi-speed
Middle speed
selection
Low speed
Jog mode
Second function selection
*3. AU terminal
Output stop
can be used
as PTC input
terminal.
Current input selection
Selection of automatic restart
after instantaneous
power failure
Contact input common (Sink*)
24VDC power supply/
max. 100mA load current
Contact input common(Source*)
*(Common for external power supply transistor)
Frequency setting signal (Analog)
3
Frequency setting
potentiometer
1/2W1k
1
*5
(+)
Auxiliary input
(-)
(+)
Terminal 4 input
(-)
(Current input)
*4. The input area can be set via
parameters. The setting
within the frame is pre-set at
the factory.
(Pr. 73, Pr. 267).
*5. It is recommended to use
2W1kΩ when the
frequency setting signal is
changed frequently.
CAUTION
To prevent a malfunction due to noise, keep the signal cables more than 10cm away from the power cables.
After wiring, wire offcuts must not be left in the inverter.
Wire offcuts can cause an alarm, failure or malfunction. Always keep the inverter clean.
When drilling mounting holes in a control box etc., take care not to allow chips and other foreign matter to enter the inverter.
4
*1. DC reactor (FR-HEL)
Remove the jumper for the
01160 or less if a DC reactor
is connected. The DC reactor
supplied with the 01800 or
more should be connected to
Earth
these terminals.
MC
R/L1
S/L2
T/L3
R1/L11
Jumper
*2
S1/L21
Earth
STF
start
STR
start
STOP
RH
RM
RL
JOG
RT
MRS
RES
Reset
AU
CS
SD
PC
10E(+10V)
10(+5V)
2
2
5
1
4
Connector
for plug-in option
connection
Option connector 1
*1
Jumper
Jumper
P1
P/+
PX
PR
N/-
ON
Connector for
with/without internal
EMC filter
OFF
Main circuit
Control circuit
*3
AU
PTC
PU
connector
0 to 5VDC
0 to 10VDC
selected
* 4
4 to 20mADC
0 to ±10VDC
* 4
0 to ±5VDC
selected
4 to 20mADC
0 to 5VDC
* 4
selected
0 to 10VDC
Terminating
resistor
*6. The CN8 connector
is provided with the
01800 or more
CN8
*6
U
V
W
Earth
C1
Terminal functions
B1
Relay output 1
vary with the output
(Alarm output)
terminal assignment
A1
(Pr. 195, Pr. 196)
C2
B2
Relay output 2
A2
RUN
Running
Terminal functions
SU
vary with the output
Up to frequency
terminal assignment
IPF
Instantaneous
(Pr. 190 to Pr. 194)
power failure
OL
Overload
FU
Frequency detection
SE
Open collector output common
Sink/source common
CA
(+)
Analog current output
(0 to 20mADC)
(-)
AM
(+)
Analog signal output
5
(0 to 10VDC)
(-)
TXD+
Data transmission
TXD-
RXD+
Data reception
RXD-
SG
GND
(Permissible load
5V
VCC
current 100mA)
Motor
M
3~
RS-485 terminal