Download Print this page

Mitsubishi Electric FR-F 740 Series Installation Manuallines page 17

Hide thumbs Also See for FR-F 740 Series:

Advertisement

Parameters
Name
33
Frequency jump 2A
34
Frequency jump 2B
35
Frequency jump 3A
36
Frequency jump 3B
37
Speed display
Up-to-frequency
41
sensitivity
Output frequency
42
detection
Output frequency
43
detection for reverse
rotation
Second acceleration/
44
deceleration time
Second deceleration
45
time
46
Second torque boost
Second V/F
47
(base frequency)
Second stall
48
prevention operation
current
Second stall
49
prevention operation
frequency
Second output
50
frequency detection
Second electronic
51
thermal O/L relay
DU/PU main display
52
data selection
CA terminal function
54
selection
Frequency
55
monitoring reference
Current monitoring
56
reference
57
Restart coasting time
58
Restart cushion time
Remote function
59
selection
Energy saving
60
control selection
65
Retry selection
Stall prevention
66
operation reduction
starting frequency
*1
The setting depends on capacities. (01160 or less/01800 or more)
*2
Setting of "9" can be made for the 01800 or more.
*3
Setting can be made for the 01800 or more.
*4
Setting of "100 to 103", "114 to 117" can be made for the 01800 or more.
Setting Range
Initial Value
0 to 400Hz,
9999
9999
0 to 400Hz,
9999
9999
0 to 400Hz,
9999
9999
0 to 400Hz,
9999
9999
0, 1 to 9998
0
0 to 100%
10%
0 to 400Hz
6Hz
0 to 400Hz,
9999
9999
0 to 3600/360s
5s
0 to 3600/360s,
9999
9999
0 to 30%, 9999
9999
0 to 400Hz,
9999
9999
0.1 to 120%
110%
0 to 400Hz,
0Hz
9999
0 to 400Hz
30Hz
0 to 500A,
9999/
9999
0 to 3600A,
1
9999 *
0, 5, 6, 8 to 14,
17, 20, 23 to 25,
0
2
50 to 57, 100 *
1 to 3, 5, 6,
8 to 14, 17, 21,
1
2
24, 50, 52, 53 *
0 to 400Hz
50Hz
Rated
0 to 500A/
inverter
1
0 to 3600A *
output
current
0, 0.1 to 5s,
9999/
9999
0, 0.1 to 30s,
1
9999 *
0 to 60s
1s
0, 1, 2, 3
0
0, 4, 9
0
0 to 5
0
0 to 400Hz
50Hz
Parameters
Name
Number of retries at
67
alarm occurrence
68
Retry waiting time
Retry count display
69
erase
Special regenerative
70
3
brake duty *
71
Applied motor
PWM frequency
72
selection
Analog input
73
selection
Input filter time
74
constant
Reset selection/
disconnected PU
75
detection/PU stop
selection
Alarm code output
76
selection
Parameter write
77
selection
Reverse rotation
78
prevention selection
Operation mode
79
selection
Motor capacity
80
(simple magnetic
flux vector control)
90
Motor constant (R1)
100
V/F1 (first frequency)
V/F1 (first frequency
101
voltage)
V/F2
102
(second frequency)
V/F2 (second
103
frequency voltage)
V/F3 (third
104
frequency)
V/F3 (third frequency
105
voltage)
V/F4
106
(fourth frequency)
V/F4 (fourth
107
frequency voltage)
108
V/F5 (fifth frequency)
V/F5 (fifth frequency
109
voltage)
PU communication
117
station number
PU communication
118
speed
PARAMETER
Setting Range
Initial Value
0, 1 to 10,
0
101 to 110
0 to 10s
1s
0
0
0 to 10%
0%
0, 1, 2, 20
0
0 to 15/
2
1
0 to 6, 25 *
0 to 7, 10 to 17
1
0 to 8
1
0 to 3, 14 to 17,
100 to 103,
14
4
114 to 117 *
0, 1, 2
0
0, 1, 2
0
0, 1, 2
0
0, 1, 2, 3, 4, 6, 7
0
0.4 to 55kW,
9999/
9999
0 to 3600kW,
1
9999 *
0 to 50Ω, 9999/
0 to 400mΩ,
9999
1
9999 *
0 to 400Hz,
9999
9999
0 to 1000V
0V
0 to 400Hz,
9999
9999
0 to 1000V
0V
0 to 400Hz,
9999
9999
0 to 1000V
0V
0 to 400Hz,
9999
9999
0 to 1000V
0V
0 to 400Hz,
9999
9999
0 to 1000V
0V
0 to 31
0
48, 96, 192, 384
192
13

Hide quick links:

Advertisement

loading