PARAMETER
Parameters
Name
PWM frequency
260
automatic
switchover
Power failure stop
261
selection
Subtracted
262
frequency at
deceleration start
Subtraction starting
263
frequency
Power-failure
264
deceleration time 1
Power-failure
265
deceleration time 2
Power failure
deceleration time
266
switchover
frequency
Terminal 4 input
267
selection
Monitor decimal
268
digits selection
Parameter for manufacturer setting.
269
Do not make setting.
Rotation direction
299
detection selection
at restarting
RS-485
331
communication
station
RS-485
332
communication
speed
RS-485
333
communication stop
bit length
RS-485
communication
334
parity check
selection
RS-485
335
communication
number of retries
RS-485
336
communication
check time interval
RS-485
337
communication
waiting time setting
Communication
338
operation command
source
Communication
339
speed command
source
Communication
340
startup mode
selection
RS-485
341
communication
CR/LF selection
Communication
342
EEPROM write
selection
*1
The setting depends on capacities. (01160 or less/01800 or more)
16
Setting Range
Initial Value
0, 1
1
0, 1, 2
0
0 to 20Hz
3Hz
0 to 120Hz,
50Hz
9999
0 to 3600/ 360s
5s
0 to 3600/ 360s,
9999
9999
0 to 400Hz
50Hz
0, 1, 2
0
0, 1, 9999
9999
0, 1, 9999
9999
0 to 31
0
(0 to 247)
3, 6, 12, 24,
96
48, 96, 192, 384
0, 1, 10, 11
1
0, 1, 2
2
0 to 10, 9999
1
0 to 999.8s,
0s
9999
0 to 150ms,
9999
9999
0, 1
0
0, 1, 2
0
0, 1, 2, 10, 12
0
0, 1, 2
1
0, 1
0
Parameters
Name
Communication error
343
count
Remote output
495
selection
496
Remote output data 1
497
Remote output data 2
503
Maintenance timer
Maintenance timer
504
alarm output set time
549
Protocol selection
NET mode operation
550
command source
selection
PU mode operation
551
command source
selection
555
Current average time
Data output mask
556
time
Current average
value monitor signal
557
output reference
current
Energization time
563
carrying-over times
Operating time
564
carrying-over times
Multiple rating
570
setting
Holding time at a
571
start
4mA Input check
573
selection
Output interruption
575
detection time
Output interruption
576
detection level
Output interruption
577
release level
Auxiliary motor
578
operation selection
Motor swichover
579
selection
MC switching
580
interlock time
581
Start waiting time
Auxiliary motor
582
connection-time
deceleration time
Auxiliary motor
583
disconnection-time
acceleration time
Auxiliary motor 1
584
starting frequency
Auxiliary motor 2
585
starting frequency
Auxiliary motor 3
586
starting frequency
Auxiliary motor 1
587
stopping frequency
Setting Range
Initial Value
0
0, 1
0
0 to 4095
0
0 to 4095
0
0 (1 to 9998)
0
0 to 9998, 9999
9999
0, 1
0
0, 1, 9999
9999
1, 2
2
0.1 to 1.0s
1s
0.0 to 20.0s
0s
Rated
0 to 500A/
inverter
1
0 to 3600A *
current
(0 to 65535)
0
(0 to 65535)
0
0, 1
0
0.0 to 10.0s,
9999
9999
1, 9999
9999
0 to 3600s,
1s
9999
0 to 400Hz
0Hz
900 to 1100%
1000%
0 to 3
0
0 to 3
0
0 to 100s
1s
0 to 100s
1s
0 to 3600s,
1s
9999
0 to 3600s,
1s
9999
0 to 400Hz
50Hz
0 to 400Hz
50Hz
0 to 400Hz
50Hz
0 to 400Hz
0Hz