Connector Pinout - GE MDS RCL220 Manual

Table of Contents

Advertisement

RCL220_manual_v3-draft.doc
Figure 18 entraNET 220 Packaged Radio Module (Bottom View)
Figure 19 entraNET 220 Packaged Radio Module (Side View)
2.3.1 DB-25 Connector Pinout
The following table describes the pinout for the DB-25 version of the PRM. Please see
"TD_RCL_Adapter_Board_Instruction_Sheet2.pdf" for information on our 03-4758A03 breakout kit for
the Access Point and Packaged Radio Module.
New DB-
Signal
25 Pin
1
COM3_DCD
2
COM2_TXD/TXD+ J3 (COM2)
3
COM2_RXD/RXD+ J3 (COM2)
4
COM2_RTS/TXD- J3 (COM2)
5
COM2_CTS
6
COM3_TXD
7
GND
8
COM2_DCD/RXD- J3 (COM2)
05-XXXXA01 Version 3 Draft
Previous PRM
Previous
Connector
PRM Pin
N/A
N/A
6
5
8
J3 (COM2)
7
N/A
N/A
J3 (COM2)
4
2
Page 15 of 79
Direction WRT MDS
Equipment
Input
Input
Output
Input
Output
Output
Input/Output
Output
9/20/2016