TIMESLOT=<number> Read/ Write for all users, starting at Administrator.
Timeslot to be used in Fixed DCM System.
Acceptable value range: 0-14
RSSI=<number> Read Only. Read last 1 second raw RSSI. The command will
automatically sync-up to a 1 second window – consecutive RSSI commands will not
be executed within the same 1 second window.
Acceptable value range: -120-0 dBm
YARDRSSI=<yardrssi> Read/ Write for all users, starting at Administrator.
Minimum in-yard RSSI value in dBm
Acceptable value range (8bits integer): -128 to 127
AUXTX=<XXX.XXXXXX> Read Only. Auxillary Transmit Frequency. Value range:
216-222 MHz, 1Hz frequency step size
Acceptable value range: 216-222 MHz Channels, 1Hz frequency step
AUXRX=<XXX.XXXXXX> Read Only. Auxillary Receive Frequency. Value range: 216-
222 MHz, 1Hz frequency step size
Acceptable value range: 216-222 MHz Channels, 1Hz frequency step
TXSTART=<txstart> Read/ Write for all users, starting at Administrator. Seconds
to timeout before transmit at boot-up. If set to 0, transmit will never start.
Acceptable value range: 0 - 30
SYNCTIMEOUT=<synctimeout> Read/ Write for all users, starting at
Administrator. Seconds to timeout when LCR not hearing repeater synch
Acceptable value range: 10 - 600
GROUPTIMEOUT=<grouptimeout> Read/ Write for all users, starting at
Administrator. Seconds to timeout when LCR[OCR] not hearing OCR[CR]
Acceptable value range: 5 - 600
CMD=<cmd> If set to 0, the command executes normally. If <cmd> is set to 1, the
command reports all settings in a format that may be copied into a configuration
script.
05-XXXXA01 Version 3 Draft
Page 43 of 79
9/20/2016