Lincoln FlowMaster A Series Instruction Manual
Lincoln FlowMaster A Series Instruction Manual

Lincoln FlowMaster A Series Instruction Manual

Single action rotary driven hydraulic pump for 5 gallon pail/container
Hide thumbs Also See for FlowMaster A Series:

Advertisement

FlowMaster™ Single Action Rotary Driven Hydraulic Pump
For 5 Gallon Pail/Container
Model: 85486 Series "A"
U. S. Patent No. 6,102,676
Foreign Patent Pending
This pump conforms to the European Directive for Product Safety
- A21
- 6H
7.5A-18110-J00
JUNE 2005
Form 403566
Page
Section
To order call 1-800-548-1191 or visit www.partdeal.com - info@partdeal.com

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the FlowMaster A Series and is the answer not in the manual?

Questions and answers

Subscribe to Our Youtube Channel

Summary of Contents for Lincoln FlowMaster A Series

  • Page 1 FlowMaster™ Single Action Rotary Driven Hydraulic Pump For 5 Gallon Pail/Container Model: 85486 Series “A” U. S. Patent No. 6,102,676 Foreign Patent Pending This pump conforms to the European Directive for Product Safety - A21 - 6H 7.5A-18110-J00 JUNE 2005 Form 403566 Page Section...
  • Page 2: Table Of Contents

    General Description must be followed. The Lincoln Industrial FlowMaster Pump Model 85486 is a fully hydraulically operated grease pump. Grease output is Operate this pump only after safety instructions and this ser- proportional to the hydraulic input flow. The pump is vice manual are fully understood.
  • Page 3: Pump Performance And Specifications

    (bar) - 450 (32) Typical installation is shown only as a guide for selecting and Hydraulic Inlet Flow, installing system components. Contact your Lincoln GPM (l/min) - Up to 7 (28) Industrial representative for assistance in designing a Pump Ratio - 10:1 system to suit your specific needs.
  • Page 4: Operation

    16. Unscrew the Plunger Tube (11) from the Outlet Pin (9). injury from injection, splashing fluid or moving parts. 17. To dismantle the Crankrod Assembly (1 through 8), Always use Lincoln Industrial parts for service and repair. remove Flat Head Screws (1) and the Counter Weights (2).
  • Page 5: Pump Dimensions

    FlowMaster™ Rotary Driven Hydraulic Pump 4. Install parts (22) through (28) into the Reciprocating Tube C. Plunger Tube (11) to Plunger Link Rod (17) - 100 to (21) after the plunger assembly (9 through 20) is 110 In.-Lbs. D. Plunger Link Rod (17) to Pump Plunger (20) - 100 to installed.
  • Page 6 FlowMaster™ Rotary Driven Hydraulic Pump Illustration #1 252725 Follower Plate Illustration #2 Page Number - 6 7.5A-18110-J00 Form 403566 To order call 1-800-548-1191 or visit www.partdeal.com - info@partdeal.com...
  • Page 7: Repair Parts List

    FlowMaster™ Rotary Driven Hydraulic Pump Repair Parts List (Common to all Models) Item Qty Description Item Qty Description Models Models 2 Flat Head Screw 1 Housing Cover 270629 (1/4 x 1-3/4) 270635 1 Cover Gasket 2 Counter Weight 272197 (Nitrile) 2 Retaining Ring 270609 4 Socket Head...
  • Page 8: Troubleshooting

    Worn wrist pin bushing 13. Check the bushings and replace if necessary. Americas: Asia/Pacific: Europe/Africa: 51 Changi Business Park One Lincoln Way Heinrich-Hertz-Str 2-8 Central 2 St. Louis, MO 63120-1578 D-69183 Walldorf © Copyright 2005 Printed in USA #09-06 The Signature...