ETEKCITY EBP-UA5 User Manual

ETEKCITY EBP-UA5 User Manual

Upper-arm blood pressure monitor
Hide thumbs Also See for EBP-UA5:

Advertisement

Upper-Arm Blood
Pressure Monitor
Model: EBP-UA5
User Manual
Questions or Concerns?
support@etekcity.com • (855) 686-3835
1

Advertisement

Table of Contents
loading

Summary of Contents for ETEKCITY EBP-UA5

  • Page 1 Upper-Arm Blood Pressure Monitor Model: EBP-UA5 User Manual Questions or Concerns? support@etekcity.com • (855) 686-3835...
  • Page 2 Upper-Arm Blood Pressure Monitor by Etekcity. If you have any questions or concerns, please reach out to our helpful Customer Support Team at support@etekcity.com. We hope you enjoy your new blood pressure monitor! BECOME AN ETEKCITIZEN Get exclusive deals, giveaways, and product registration.
  • Page 3: Table Of Contents

    Table of Contents Package Contents Package Contents 1 x Blood Pressure Monitor Specifications 1 x Arm Cuff Safety Information 1 x Type-C USB Charging Cable Function Diagram 1 x Storage Bag Digital Diagram 1 x Quick Start Guide Getting to Know Your Blood Pressure Monitor - When to Take Blood Pressure - Selecting a User - Memory...
  • Page 4: Specifications

    Specifications Pressure: 0–290 mmHg / 0–39 kPa Measurement Range Pulse: 40–199 per minute Pressure: 3 mmHg / 0.4 kPa Accuracy Pulse: 5% Units mmHg / kPa Monitor: 4.9 x 4.5 x 2.8 in / 12.6 x 11.5 x 7.1 cm Cuff: 24.5 x 5.9 in / 62 x 15 cm Dimensions Cuff Circumference: 8.7–16.5 in / 22–42 cm...
  • Page 5: Safety Information

    Safety Information • Do not use the monitor near HF surgical equipment, MRI, CT scanner, or in an oxygen rich environment. Please read and follow all instructions and safety • Closely supervise children near the monitor. guidelines in this manual. Do not allow children to use or play with this monitor.
  • Page 6 Safety Information (cont.) • Do not take measurements more than • Do not hit or drop the monitor. necessary. It may cause bruising due to blood • Do not use the monitor in a moving vehicle, flow interference. such as a car or an airplane. •...
  • Page 7: Function Diagram

    Function Diagram Display Air Port Type-C Charging Port Set/User Button Start/Stop Button Memory Button Air Plug Air Hose Type-C USB Charging Cable Cuff...
  • Page 8: Digital Diagram

    Display Diagram Battery User Systolic Blood Pressure Diastolic Blood Pressure Irregular Heartbeat Indicator Pulse Cuff Status WHO Indicator...
  • Page 9: Getting To Know Your Blood Pressure Monitor

    Getting to Know Your Blood Pressure Monitor Blood pressure monitors use the oscillometric Selecting a User method of measuring blood pressure. The monitor can detect the blood’s movement through the To switch between user 1 and 2: brachial artery and convert it into a digital reading. The monitor is easy and simple to use and does not •...
  • Page 10: Memory

    Memory Turning the Speaker On/Off Results are automatically saved after each While the monitor is off, press and hold measurement. The monitor can save up to 90 until the display reads “SP OFF”. [Figure 1.1] results for each user. Press to change the reading to “SP ON”...
  • Page 11: Changing Units

    Before Measurement Changing Units While the monitor is off, press and hold • Sit on a chair with your feet flat on the floor and until the display reads “SP OFF” or “SP ON”. your arms on the table so the cuff is level with your heart.
  • Page 12: Using The Blood Pressure Monitor

    Using the Blood Pressure Caution Monitor • Do not measure blood pressure until at least 30 minutes after physical activity. Do not drink stimulating beverages, such as coffee or alcohol, Note: Before first use, fully charge the blood or smoke before measurement. pressure monitor (see Charging the Battery, •...
  • Page 13 Using the Blood Pressure Monitor (cont.) Place your arms on a surface so the cuff is at Note: the same level as your heart. Your arms should • Press at any time to stop measuring. be in a relaxed, natural position. •...
  • Page 14: Display Readings

    Display Readings Symbol Solution Air may be leaking or pulse may be too weak. Reattach the cuff and test again. Blood pressure cannot be detected due to interference. Make sure you are seated and positioned correctly before testing again. The measurement result is not correct. Test again. Inflation has failed.
  • Page 15: Blood Pressure Classification Table For Adults

    Blood Pressure Classification Table for Adults According to the 2017 Guideline for the Prevention, Detection, Evaluation and Management of High Blood Pressure in Adults, there are 4 levels for blood pressure classification and 2 hypertensive crises: emergencies and urgencies. BP Classification Systolic (mmHg) Diastolic (mmHg) Normal Blood...
  • Page 16: Maintenance

    Maintenance Note: Charging the Battery • Charging may take 3–4 hours. The blood pressure monitor comes with a rechargeable Li-ion battery inside. Use the included • Every 2 months (or when battery life is Type-C USB cable to charge the monitor. will significantly shorter), fully charge the monitor appear on the screen when the monitor needs to be...
  • Page 17 Optimizing Battery Performance Storage For best results allow the monitor to go through 2 • Turn the monitor off and unplug the air plug full charge and use cycles. from the air port. • Place the cuff and the machine in the storage Fully charge the battery.
  • Page 18: Frequently Asked Questions

    Frequently Asked Questions Why are my blood pressure readings different? Why are the blood pressure readings different every time I measure? • The area you are in as well as your mental and physical state both factor into your readings. •...
  • Page 19: Glossary Of Symbols

    Glossary of Symbols Electrical devices are recyclable material and Storage humidity range: should not be disposed of with household Lower limit: 15%RH waste after their useful life. Help us protect the Upper limit: 93%RH environment and save resources by taking this device to the appropriate collection point.
  • Page 20 IMPORTANT INFORMATION REGARDING ELECTROMAGNETIC COMPATIBILITY (EMC) • This product needs special precautions regarding electromagnetic compatibility (EMC) and needs to be installed and put into service according to the EMC information provided, and this unit can be affected by portable and mobile radiofrequency (RF) communications equipment. •...
  • Page 21 Guidance and Manufacturer’s Declaration – Electromagnetic Emission The EBP-UA5 Upper-Arm Blood Pressure Monitor is intended for use in the electromagnetic environment specified below. The customer or the user of the EBP-UA5 Upper-Arm Blood Pressure Monitor should assure that it is used in such an environment.
  • Page 22 EQUIPMENT and SYSTEMS The EBP-UA5 Upper-Arm Blood Pressure Monitor is intended for use in the electromagnetic environment specified below. The customer or the user of the EBP-UA5 Upper-Arm Blood Pressure Monitor should assure that it is used in such an environment.
  • Page 23 ; 1 cycle and during power mains interruptions, it is 70 % U ; 25/30 cycles power supply input recommended that the EBP-UA5 Upper- lines IEC 61000-4-11 Single phase: at 0° Arm Blood Pressure Monitor be powered 0 % U ;...
  • Page 24 Compliance Level Electromagnetic Environment - Guidance Portable and mobile RF communications equipment should be used no closer to any part of the EBP-UA5 Upper- Arm Blood Pressure Monitor, including cables, than the recommended separation distance calculated from the 3 V rms equation applicable to the frequency of the transmitter.
  • Page 25 To assess the electromagnetic environment due to fixed RF transmitters, an electromagnetic site survey should be considered. If the measured field strength in the location in which the EBP-UA5 Upper-Arm Blood Pressure Monitor is used exceeds the applicable RF compliance level above, the EBP-UA5 Upper-Arm Blood Pressure Monitor should be observed to verify normal operation.
  • Page 26 The EBP-UA5 Upper-Arm Blood Pressure Monitor is intended for use in an electromagnetic environment in which radiated RF disturbances are controlled. The customer or the user of the EBP-UA5 Upper-Arm Blood Pressure Monitor can help prevent electromagnetic interference by maintaining a minimum distance between portable and mobile RF communications equipment (transmitters) and the EBP-UA5 Upper-Arm Blood Pressure Monitor as recommended below, according to the maximum output power of the communications equipment.
  • Page 27 For transmitters rated at a maximum output power not listed above, the recommended separation distance d in meters (m) can be estimated using the equation applicable to the frequency of the transmitter, where P is the maximum output power rating of the transmitter in watts (W) according to the transmitter manufacturer.
  • Page 28: Warranty Information

    Some states do not allow this exclusion or limitation of incidental or consequential losses so the foregoing Etekcity Corporation warrants all products to be of the highest quality in disclaimer may not apply to you. This warranty gives you specific legal...
  • Page 29 Warranty Information (cont.) Additional 1-Year Warranty You can extend your 1-year warranty by an additional year. Log onto www.etekcity.com/warranty to register your new product for the extended warranty. Please fill out all required fields and include your order ID, place of purchase, and purchase date, if applicable.
  • Page 30: Customer Support

    If you have any questions or concerns about your new product, please contact our helpful Customer Support Team. Customer Support Support Hours Distributed by Etekcity Corporation Monday—Friday 1202 N. Miller St., Suite A 9:00 am —5:00 pm PST/PDT Anaheim, CA 92806 *Please have your invoice and order ID ready before Email: support@etekcity.com...
  • Page 31 Connect with us @Etekcity...
  • Page 32 Building on better living. V1.1_20190709...

Table of Contents