Magnetic position detectors for "t" grooves reed switch type/for "t" grooves magneto-resistive (mr)

Advertisement

Available languages
  • EN

Available languages

  • ENGLISH, page 9
MOUNTING RECOMMENDATIONS
Make sure that the power cable for the detector is not subject to tension
or torsional stress throughout its lifetime.
- Avoid using cables which are not long enough.
- Do not pull on the cables.
- Do not fold the cables.
- Observe a minimum bending radius of 15 mm in static assembly.
- Do not pinch the cables when using a retaining ring plier. The minimum
tightening torque must be observed (for cable dia. 2 – 2.5 mm).
- Do not mount position detectors near to ferromagnetic or intense elec-
tromagnetic fi elds (solenoid coil, soldering tongs etc.).
- Check to ensure the compatibility of the PUR and PVC cables with the
oil and solvent environments (contact us, if necessary). Clean with an
alcaline solution (soapy water).
Flexible applications:
In dynamic assembly the cable is subject to oscillating movements due to the weight of the connectors or excess
cable lengths which may cause the cable to break. We recommend using the cable cover and holder (available as
accessory) in the groove and observing a minimum cable bending radius of 120 mm.
PUTTING INTO SERVICE
- Observe the maximum/minimum (electrical, mechanical, temperature) operating ranges defi ned in this documentation.
- Any modifi cation to the equipment shall be subject to the prior approval of ASCO NUMATICS.
DIMENSIONS
The magnetic detector fi ts directly into the grooves in the cylinder body. Detection of very small movements or
very short strokes requires one detector to be installed in each groove.
34
5
INSTALLATION RECOMMENDATION
In order to control the max. end of cylinder stroke,
the detectors must be mounted in the following
direction:
PES cylinders series 453:
Ø 32-100 : cable oriented towards the cylinder bar-
rel.
6
Min.
To the fi xed part