Download Print this page

Emerson REED Series Manual page 13

Magnetic position detectors for "t" grooves reed switch type/for "t" grooves magneto-resistive (mr)

Advertisement

Available languages
  • EN

Available languages

  • ENGLISH, page 9
ASSEMBLY AND DISASSEMBLY PROCEDURE FOR T-SLOT DETECTORS
DETECTOR ASSEMBLY
A
90°
D
0,5 Nm
A - Turn the detector's knurled nut by 90° so that it is retracted inside.
B - Press the detector down into the groove.
C - Position the detector at the desired sensing point.
D - Hold the detector in place as you tighten the screw (½ turn).
Max. screw tightening torque: 0,5 N.m
E - Fix the adjustment position with the memory unit and secure the cable into the groove with the clip.
DETECTOR DISASSEMBLY/REASSEMBLY
1 - Loosen the knurled nut by 90° and remove the cable from the clip.
2 - The following installation, adjustment and tightening steps are identical to steps B, C and D described above.
B
E
0,6 x 3,5 mm
Clip
5
C