Electrical Install

An electrician must provide electrical service as specified in conformance with all local, state, and federal electrical
codes.
Step 1: Plug the unit into the power source.

Initial Start-Up

Step 1. Insert an empty funnel into the funnel rails.
Step 2. Place an empty server under the funnel.
Step 3. Connect the brewer to the power source.
Step 4. Turn master on/off switch to the on position, located on the side or rear of the machine if equipped.
Step 5. Press and release the BrewOn/Off Switch. Water will flow into the tank and stop when the tank is filled to its
capacity. Display will show "PLEASE WAIT...TANK FILLING" until tank is filled with water.
Step 6. Wait approximately twenty minutes for the water in the tank to heat to the proper temperature. Display will
show "READY TO BREW...WATER TEMP: 200°" when tank is at operating temperature. Some water
will drip from the funnel during this time; this is due to expansion and should not occur thereafter.
Step 7. Place a small container beneath the faucet and open the faucet handle. Release it when you hear the tank
refilling.
Step 8. Water volumes and flow settings have been preset at the factory. Refer to adjustments for the Set Brew
Ounces section of this manual should the volume need to be increased or decreased.
Step 9. The brewer is now ready for user setup.
Step 10. Repeat steps 5-9 for remaining side on Twins.
Brew water temperature is factory set at 200°F (93.3°C).
Areas of high altitude will require lowering this temperature
to prevent boiling. This chart should be used as a guide when
re-adjusting the brew water temperature.
Brew water temperature is factory set at 200 °F (93.3°C)
Areas of high altitude will require lowering this tempera
ture to prevent boiling. This chart should be used as a
guide when readjusting the brew water temperature.
Altitude
Boiling point
of water
(Feet)
F
C
-1000
213.8
101.0
-500
212.9
100.5
0
212.0
100.0
500
211.1
99.5
1000
210.2
99.0
1500
209.3
98.5
2000
208.4
98.0
2500
207.4
97.4
3000
206.5
96.9
3500
205.6
96.4
4000
204.7
95.9
4500
203.8
95.4
5000
202.9
94.9
5500
201.9
94.4
6000
201.0
93.9
6500
200.1
93.4
7000
199.2
92.9
7500
198.3
92.4
8000
197.4
91.9
8500
196.5
91.4
9000
195.5
90.8
9500
194.6
90.3
10000
193.7
89.8
Bunn-O-Matic Corporation
Recommended
water temperature
F
C
200
93.3
200
93.3
200
93.3
200
93.3
200
93.3
200
93.3
200
93.3
200
93.3
199
92.8
198
92.2
197
91.7
196
91.1
195
90.6
195
90.6
194
90.0
193
89.4
192
88.9
191
88.3
190
87.8
189
87.2
188
86.7
187
86.1
186
85.6