Bunn Axiom-APS SERIES Installation & Operating Manual

Bunn Axiom-APS SERIES Installation & Operating Manual

Axiom series

Advertisement

Axiom-APS SERIES
(Starbucks)
INSTALLATION & OPERATING GUIDE
BUNN-O-MATIC CORPORATION OF CANADA
280 INDUSTRIAL PARKWAY SOUTH,
AURORA, ONTARIO, L4G 3T9
PHONE: (905) 841-2866 FAX: (905) 841-2775
To ensure you have the latest revision of the Operating Manual, or to view the Illustrated Parts
Catalog, Programming Manual, or Service Manual, please visit the Bunn-O-Matic website, at
www.bunn.com. This is absolutely FREE, and the quickest way to obtain the latest catalog and
manual updates. For Technical Service, contact Bunn-O-Matic Corporation at 1-800-286-6070.
39130.7001B 06/10 ©2008 Bunn-O-Matic Corporation

Advertisement

Table of Contents
loading

Summary of Contents for Bunn Axiom-APS SERIES

  • Page 1 To ensure you have the latest revision of the Operating Manual, or to view the Illustrated Parts Catalog, Programming Manual, or Service Manual, please visit the Bunn-O-Matic website, at www.bunn.com. This is absolutely FREE, and the quickest way to obtain the latest catalog and manual updates. For Technical Service, contact Bunn-O-Matic Corporation at 1-800-286-6070.
  • Page 2: Warranty

    SOLE OPTION AS SPECIFIED HEREIN, TO REPAIR, REPLACEMENT OR REFUND. In no event shall BUNN be liable for any other damage or loss, including, but not limited to, lost profi ts, lost sales, loss of use of equipment, claims of Buyer’s customers, cost of capital, cost of down time, cost of substitute equipment, facilities or services, or any other special, incidental or consequential damages.
  • Page 3: Table Of Contents

    To reduce the risk of electric shock, Authorized service personnel only. Disconnect power before servicing. do not remove or open cover. PN: 00658.0000G 02/08 © 1985 BUNN-O-MATIC CORPORATION No user-serviceable parts inside. #00658.0000 #37881.0002 As directed in the International Plumbing Code of the...
  • Page 4: Electrical Requirements

    ELECTRICAL REQUIREMENTS WARNING - The brewer must be disconnected from the power source until specifi ed in Initial Set-Up. Refer to Data Plate on the Brewer, and local/national electrical codes to determine circuit requirements. ELECTRICAL HOOK-UP (All Models) CAUTION – Improper electrical installation will damage electronic components. An electrician must provide electrical service.
  • Page 5: Single/Dual Volt Models

    ELECTRICAL REQUIREMENTS Single & Dual Volt Models Requirements for brewers with an attached cord set are as follows: Dual Voltage Switch in Note: This electrical service re- 120V position quires 2 current carrying conduc- tors (Neutral, and L1) and a separate conductor for earth ground.
  • Page 6: Plumbing Requirements & Initial Set-Up

    " water supply line. A tight coil of copper tubing in the water line will facilitate moving the brewer to clean the counter top. Bunn-O-Matic does not recommend the use of a saddle valve to install the brewer. The size and shape of the hole made in the supply line by this type of device may restrict water fl ow.
  • Page 7: Operating Controls & Coffee Brewing

    COFFEE BREWING 1. Begin each brew cycle with a clean empty brew funnel. 2. Insert a BUNN fi lter into the funnel. 3. Pour (or grind) fresh coffee into the fi lter and level the bed of grounds by gently shaking.
  • Page 8: Cleaning & Tank Drain

    1. The use of a damp cloth rinsed in any mild, nonabrasive, liquid detergent is recommended for cleaning all surfaces on Bunn-O-Matic equipment. 2. Check and clean the sprayhead. The sprayhead holes must always remain open. Insert the short end of the sprayhead cleaning tool into each of the fi...
  • Page 9: Adjustments & Optional Settings

    ADJUSTMENTS & OPTIONAL SETTINGS READY TO BREW WATER TEMP: 200° Using the menu-driven display on the front of the brewer, the operator has the ability to alter or modify various brewing parameters such as brew lockout, brew volume, brew strength, etc. This allows for the precise brewing of various fl...
  • Page 10 ADJUSTMENTS & OPTIONAL SETTINGS (CONT.) PROGRAMMING FUNCTIONS - FLOW CHART BrewWIZARD BREW LOCKOUT ? SELECT RECIPE ? ENTER SERIAL # ? DONE ENTER SERVICE #? ENTER PASSWORD EXITING BrewWIZARD SET PASSWORD BREW OZ: 110.0 BREW METER DONE SET PULSE BREW ? DRIP T I M E 0:30 SET TEMP: 200°...
  • Page 11 FLOW CHART (CONT.) SET READY: 195° SET LANGUAGE ? UNITS DONE METRIC DONE ENG Enabl EnergySavr ENABLE CLEAN ENTER ASSET # ? DONE YES DONE EnableFreshTimer ENABL WARMER OFF REFILL DONE YES DONE DONE (These two screens will change if "BrewLogic" is enabled) ENABLE BrewLOGIC SPRAY OZ/M: 25.0...

Table of Contents