Step 9: Calibrate Sprayhead.
□ Enter Level 2 programming.
□ Scroll to the Calibrate Flow screen. This test is used to capture water from the sprayhead during a pre-deter
mined 60 second dispense valve cycle.
CALIBRATE FLOW ?
NO
YES
□ Ensure the sprayhead and funnel are in place and put a container, measuring pitcher or server, underneath the
funnel, select Yes.
CONTAINER
RDY ?
QUIT
YES
□ To activate the flow rate check, press the Brew button.
□ The valve will open for 60 seconds. Once all of the water has dripped out, use the (-) or (+) buttons to input the
volume collected and select Done.
ENTER OZ:
24.5
(-)
DONE
(+)