Error Codes; Drain Line - AFWFilters Fleck 5600 Installation Instruction

Table of Contents

Advertisement

After installing the bypass it still moves up and down, is that normal?
Yes. The bypass seals with O-ring and even when tightened down some movement will
occur, without leaking. The system requires this movement to allow for pressure changes in
DO NOT OVERTIGHTED THE BYPASS VALVE. As long as the screws are snug
the system.
enough to keep the bypass from coming apart further tightening will just cause damage.
D
L
RAIN
INE
Can I run my drain line to a sewer/septic?
Yes. These systems can be ran to your sewer or septic line and is typically the
recommended place to run the drain. Most concerns are related to the amount of water
going down the drain, and a properly designed septic/sewer system will not have a
problem handling it. Studies have also shown that concerns over salt in the wastewater
affecting septic systems are unfounded and not a problem.
Can my drain line be ran vertically?
Yes. Water from the drain comes out under pressure and can be ran vertically if needed.
D
D
IGITAL
ISPLAY
Why does my display flashing between the time of day and a number?
This is normal, with the number displayed indicating the number of gallons until the
next regeneration.
What does the faucet icon mean?
That is the service icon, meaning the system is in service. It does NOT mean the system
needs service. If it is flashing then a regeneration is queued for the next set time.
What does the water drop icon mean?
That is the flow icon. Only used on metered softners, it indicates water is flowing
through the system.
What does the circled exclaimation icon mean?
That indicates an error. Match the number on your display with the number on the error
chart below for troubleshooting tips.
Error
Error Type
Code
SXT Error Codes
Cause
26 of 28
Solution