Sxt User Programming Chart - AFWFilters Fleck 5600 Installation Instruction

Table of Contents

Advertisement

Meter
K
Pulse
Setting
Pressing the extra cycle button after the final setting will save your
changes. If no buttons are pressed for 60 seconds while in
programming mode the changes will be cancelled.
> If you accidentally change a setting that does not have a
recommended or variable value: Please do a hard reset as outlined in
the resets section to return all values to default. You can then go
back through the programming to set it up according the the chart
Once you have finished programming use the arrows to set the current time of day.
Once the time is set the display should then show the service icon, with the data
display flashing between the current time of day and remaining system capacity.
As water flows through the system the flow indicator will flash and the system
capacity will count down. Once it reaches 0 the system will queue a regeneration
for the set time. A flashing service icon indicates that a regeneration is queued. A
manual regeneration can be queued by pressing the extra cycle button. An
immediate regeneration can be initiated by holding the extra cycle button for
about 5 seconds. THE SERVICE ICON INDICATES THAT THE SYSTEM IS "IN
SERVICE" AND FUNCTIONING CORRECTLY, IT DOES NOT MEAN THAT THE SYSTEM
NEEDS SERVICE.
After intial setup the master programming should not need to be used again unless
a system reset is performed. Even in the event of a power outage all settings are
retained. If your water use or water quality changes you can use the user
programming to make common changes to the programming as lined out below.
-Ensure the time is NOT set to 12:01pm, hold BOTH up and down
Please refer to the master programming chart for proper values each
3/4" Turbine Meter For the smaller meter
-t0.7-
used on some softeners. Not as common
0.1-999.9

SXT User Programming Chart

arrows until programming icon appears-
as the paddle wheel meter.
Pulses per gallon. Only applies to
systems with FM set to Gen, not
typically used.
above.<
setting.
18 of 28