Siemens MJ-5 Installation And Operation Manual page 38

Voltage regulator control panel
Hide thumbs Also See for MJ-5:
Table of Contents

Advertisement

4 Setting Up the MJ-5 Control Panel
Table 4.10 Communications Module Configuration Items
DATA ITEMS
DESCRIPTION
DatPortBaud
Local Data Port transmission rate
Data Parity
Local Data Port Parity Setting
DataPortAddr
Enables/Disables Addressing for Data Port
Reg ID
Regulator Identification Number (Note: This is NOT the address for
Data Port Communications)
Protocol
Communications Module Protocol
CommBaud
Communications Module transmission rate
CommParity
Communications Module Protocol
CommAddr
Communications Module Address
Resync Time
Communications Module resync time (in characters). Used for
Communications Module protocols 2200 and 2179 to determine
when one message ends and another message begins
TxEnDelay
Communications Module Transmit Enable Delay (in milliseconds),
Specifies the amount of time between the RTS output being activated
and the start of transmit (output) data.
DnpDlConfirm
DNP Data Link Confirm
SW repeat
Enable Fiber loop
HostAddr
Host Address for Unsolicited Responses
CMUnsolicited
Unsolicited Responses
AutoInhEnable
Auto Inhibit Enables (Y) Remote Raise/Lower. If disabled, (N)
activates automatic operation
DNP set
Select a predefined or custom DNP point set
Deadband CL-1
Class 1--Used to set band without configuration tool
Deadband CL-2
Class 2---Used to set band without configuration tool
Deadband CL-3
Class 3---Used to set band without configuration tool
CommType
Describes the type of communication
IP config
Enables/Disables IP Configuration Selection
IP-192:168:001:200
Displays current IP address
NM-
Displays current Network Mask
255:255:255:000
GW-
Displays current Gateway
000:000:000:000
TCP port
DNP Communication Port Number
Note: If both the Data Port and the Communications
Module are simultaneously set up for remote communications, then the Data Port restrictions
on the value of the "Comm Addr" data item must apply.
Siemens Industry, Inc.
SELECTIONS
300, 1200, 2400, 4800, 9600, or 19200
EVEN or NONE
OFF or ON
NNNNN (Range 0-32765)
DNP3.0, 2200, 2200NPA, MJ3A A, MJ3A B1, MJ3A
B2, 2179, and Special
300,1200,2400,4800,9600 or 19,200
NONE, EVEN, ODD
NNNN (range:0-32765)
NNN (range 0-250, 1)
NNN (range 0-250)
Y or N
Y or N
NNN (range 0-65535)
Y or N
Y or N
DNPcfg. 2x3, 2x4, etc.
00.0 or NN.N
00.0 or NN.N
00.0 or NN.N
Network, Serial, Fiber-serial or RS-485
Static or DHCP
192.168.1.200 or xxx.xxx.xxx.xxx
255.255.255.0 or
xxx.xxx.xxx.xxx
192.168.1.1 or xxx.xxx.xxx.xxx
20,000 or NN,NNN (not advisable to change)