Siemens MJ-5 Installation And Operation Manual page 20

Voltage regulator control panel
Hide thumbs Also See for MJ-5:
Table of Contents

Advertisement

4 Setting Up the MJ-5 Control Panel
Table 4.2 The <ADV CONFIGURE> menu
DATA ITEM
DESCRIPTION
Meter Volts
Display Primary or Secondary volts
I Threshold %
Tap change minimum current
I Shift
Current shift for reverse power flow
I Load Max
Max. Load Current (for Overcurrent)
PT Threshold
Tap change low voltage limit
Time
Time of day
Date
Date
Format
Date format
Daylight Savings
Daylight Savings Time
Dmd Type
Method for determining Demand
Dmd Time
Demand Period length (minutes)
Dmd Subperiods
Number of Demand subperiods
Min/Max t.o.
Min/Max display timeout (seconds)
Screen t.o.
Show default display screen (min.)
Quick t.o.
Quick menu display timeout (second)
QuickDispTim
Quick menu slideshow time (second)
AutoVari-Amp
Automatic Vari-Amp Protection
SoftVari-Amp
Sofware Vari-Amp setting
R Limit
Raise Limit (Alert & Soft Vari-Amp)
L Limit
Lower Limit (Alert & Soft Vari-Amp)
Slave Master
Put two tap changer in locked step
(Ref. Comm. Manual Section 8)
Tap Alert
Enable or disable tap alerts
Alrt M=
Metering
Alrt C=
Control
Alrt S=
System
Tap Resync
Synchronizes tap position at Neutral
Comm AutoInh
Turns SCADA auto inhibit ON or OFF
Lower LED
Raise Lower Indicator Functionality
P2 Calc
P2 Calculation
U2/P2 Out
Load Voltage Terminal Locking
I Dir Bias
Current Bias Functionality
Bias %
Current Bias Percent
Remote BTN
Remote/Local Button Functionality
Macntrl
Master slave control voltage
(Ref. Comm. Manual Section 8)
Siemens Industry, Inc.
VALID INPUTS
SEC, PRI
0% to 10 %
0˚ to 359˚
0% to 350%
0 to 134
HH:MM:SSA/P
NN/NN/NN
Mo/Da/Yr or Da/Mo/Yr
ON or OFF
THERMAL or WINDOW
1 to 999
1 to 99 (For Sliding Window mode only)
1 to 99
1 to 99
1 to 59
1 to 10
ON or OFF
ON or OFF
10, 8
, 7
, 6
, 5 %
10, 8
, 7
, 6
, 5 %
OFF,MA,Sl,S2
ENABLE or DISABLE
Y (to enable) or N (to disable)
Y (to enable) or N (to disable)
Y (to enable) or N (to disable)
ON or OFF
ON or OFF
Solid, Blink
ON, OFF
VLoad, Toggle, U2, P2
None, Fwd, Rev, Neut T
0 to 10%
Enabled, Disabled
Master, Highest, Lowest, Average
DEFAULT
INC
SEC
---
0%
1%
1 ˚
350%
1%
90
1%
---
---
---
---
Mo/Da/Yr
---
ON
----
THERMAL
---
30
1
Minute
6
1
15
1
Second
5
1
Minute
10
1
Second
2
1
Second
OFF
---
OFF
---
10%
1
%
10%
1
%
OFF
ENABLE
---
Y
---
Y
---
Y
---
OFF
---
OFF
---
Solid
---
ON
---
VLoad
---
None
---
0%
---
Enabled
---
16

Hide quick links: