GTWIN 2-wire
installation
system manual
Code 5012 345
2
TGTWIN SYSTEM MANUAL EN
Building 1
LINE OUT
LINE IN
1
2
3
4
IN1
LINE
MC-Gtwin
column
multiplexer
IN0
LINE IN LINE OUT
Following buildings
REV.0219

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the Gtwin Series and is the answer not in the manual?

Questions and answers

Summary of Contents for golmar Gtwin Series

  • Page 1 Building 1 LINE OUT LINE IN LINE MC-Gtwin column multiplexer LINE IN LINE OUT Power supply FA-Gtwin Following buildings Power supply FA-Gtwin GTWIN 2-wire installation system manual Code 5012 345 TGTWIN SYSTEM MANUAL EN REV.0219...
  • Page 2: Table Of Contents

    GTWIN SYSTEM MANUAL CONTENTS GENERAL CHARACTERISTICS AND STANDARDS................3-4 TYPES OF SYSTEM..........................4-8 SYSTEM OPERATION..........................9 ontrol of calls and busy state ......................Door panel functions........................9-10 Monitor/telephone functions......................11-12 SYSTEM INSTALLATION........................13 Safety precautions..........................13 Minimum and maximum number of devices.................. 13-14 System power supply........................
  • Page 3: General Characteristics And Standards

    GTWIN SYSTEM MANUAL Gtwin video door entry system with simplified wiring (non-polarised 2-wire bus). Its modular structure enables the forming of small systems of 1 or 2 apartments and also large systems of different types and dimensions: dwe audio, video or mixed, offering suitable solutions to all requirements. GENERAL CHARACTERISTICS AND TYPES OF SYSTEM With the Gtwin system, it is possible to form video door entry installations of up to 127 users per MC-Gtwin multiplexer, with a maximum of 32 MC-Gtwin multiplexers, each with a maximum of 2 secondary panels...
  • Page 4: Types Of System

    GTWIN SYSTEM MANUAL TYPES OF SYSTEM Building with 1 main access and 1 column (without multiplexer) LINE OUT LINE IN LINE 1 Access panel (main) SW1 (ID) = 0 LINE 2 FA-Gtwin power supply Building with 2 main accesses or 1 main and 1 secondary, maximum 4 columns (1 MC-Gtwin column multiplexer) LINE OUT LINE IN...
  • Page 5 GTWIN SYSTEM MANUAL Building with 4 main accesses and maximum 4 columns (1 DPM-Gtwin panel multiplexer) LINE OUT LINE IN LINE FA-Gtwin power supply FA-Gtwin DPM-Gtwin panel multiplexer power supply SW1 (ID) = 0 SW1 ( ) = 1 SW1 ( ) = 2 SW1 ( ) = 3 Access panels (main)
  • Page 6 GTWIN SYSTEM MANUAL 1 main general access and 1 secondary access in each building, maximum 64 columns, 16 buildings (16 MC-Gtwin multiplexers) Building (n) Building (n+1) LINE OUT LINE OUT LINE IN LINE IN Secondary panel SW1 (ID) = n SW2 ( AUX dip 2 = 0 LINE...
  • Page 7 GTWIN SYSTEM MANUAL 4 general accesses as main and 1 or 2 secondary accesses in each building, maximum 128 columns, 32 buildings (32 MC-Gtwin multiplexers) Building (n) Building (n+1) Building (n+2) LINE OUT LINE OUT LINE OUT Secondary panel LINE IN LINE IN LINE IN SW1 ( )
  • Page 8 GTWIN SYSTEM MANUAL 4 general accesses as main, 1 or 2 secondary accesses in each building and a guard unit, maximum 128 columns, 32 buildings (32 MC-Gtwin multiplexers) Building (n) Building (n+1) Building (n+2) LINE OUT LINE OUT LINE OUT Secondary panel LINE IN LINE IN...
  • Page 9: System Operation

    GTWIN SYSTEM MANUAL SYSTEM OPERATION CONTROL OF CALLS AND BUSY CHANNEL The Gtwin system enables several simultaneous conversations to take place in the different interior buildings, in addition to another conversation between a main general panel and a monitor/telephone in an interior building that is not in a busy channel.
  • Page 10 GTWIN SYSTEM MANUAL CONTROL OF MAIN DOOR OPENING The door panel's terminals (SE-, SE+) enable the connection of a 12V DC electric lock (Golmar), without the need for an additional power supply. Activation of the electric lock: - Each time the entrance hall button is activated (PA terminals).
  • Page 11: Monitor/Telephone Functions

    GTWIN SYSTEM MANUAL MONITOR/TELEPHONE FUNCTIONS § For the particular features of the monitor/telephone, see the corresponding manual. RECEIVING CALLS When a call is received in the apartment, the monitor/telephone rings with the melody set (one of 5 options) with these intervals: Call origin Time Total bell duration...
  • Page 12 GTWIN SYSTEM MANUAL Ÿ Busy channel (monitor/telephone busy): The monitor/telephone that makes the call emits 4 fast tones (4 beeps) indicating that the unit called is busy. Hang up and try later. CALL FROM THE INTERIOR DOOR OF THE APARTMENT FUNCTION The monitor/telephone has a terminal input (CP) for the connection of a call button (doorbell) of the interior door of the apartment.
  • Page 13: System Installation

    GTWIN SYSTEM MANUAL SYSTEM INSTALLATION SAFETY PRECAUTIONS • Always disconnect the power supply before installing or making modifications to the devices. The fitting and handling of these devices must be carried out by authorised personnel. All wiring must run at least 40 cm away from any other wiring. On the power supply unit: - Do not overtighten the screws on the connector.
  • Page 14 GTWIN SYSTEM MANUAL Maximum 32 distributors per column/riser Maximum 127 monitors/ Maximum 32 monitors/telephones telephones per column/riser per column nitores Maximum 4 monitors/telephones connected in input/output mode Maximum 16 monitors/telephones per column/riser Maximum 4 monitors/telephones connected in input/output mode...
  • Page 15: System Power Supply

    GTWIN SYSTEM MANUAL SYSTEM POWER SUPPLY To calculate the number of power supplies required for the system, the following should be considered: Ÿ System with a column/riser with 1 or 2 access panels with 122 buttons (apartments) each, up to 127 monitors/telephones, 1 column multiplexer: 1 FA-Gtwin power supply.
  • Page 16: Types Of Usable Cable

    FA-Gtwin power supply TYPES OF USABLE CABLE The bus is NOT polarised. The Golmar RAP-GTWIN cable has been specially designed to ensure the system's maximum distance and extension. The twisting of the cable also ensures good immunity from interference. §...
  • Page 17: Distances And Maximum Sums

    GTWIN SYSTEM MANUAL DISTANCES AND MAXIMUM SUMS CONNECTION OF COLUMNS/RISERS WITH TELEPHONES ONLY This chapter describes the different modes of connection of a column/riser with telephones only, regardless of whether the column or riser is connected to a FA-Gtwin power supply, MC-Gtwin column multiplexer or DPM- Gtwin panel multiplexer.
  • Page 18 GTWIN SYSTEM MANUAL Bc = distancia entre el dispositivo desde donde está conectada la columna / troncal y el teléfono más leja o distance Compatibility of cables and cross-sections of users 600m RAP-GTWIN cable (for new installations) 300m Telephone cable Ø 0.6 mm without cover 200m CAT5 UTP (twisted pair) 300m...
  • Page 19 GTWIN SYSTEM MANUAL CONNECTION OF THE AUDIO DOOR ENTRY SYSTEM WITH TELEPHONES ONLY (1 BUILDING) This chapter describes the different connection modes of the door panels in systems with telephones only (1 building). § The instructions described below are valid only for fully audio systems. 1 column/riser with an access panel and 1 power supply column/riser maximum 127 users Ax+Bc...
  • Page 20 GTWIN SYSTEM MANUAL istanc Compatibility of cables and cross-sections RAP-GTWIN cable (for new installations) 400m 800m Telephone cable Ø 0.6 mm without cover 100m 600m CAT5 UTP (twisted pair) 100m 800m HVV05-F cable hose 1.5 mm 300m Cable cross-section 1 mm 150m (*) The sum of all of the Bus wiring in the installation is obtained with the sum of all of the component parts...
  • Page 21 GTWIN SYSTEM MANUAL CONNECTION OF COLUMNS/RISERS WITH MONITORS/TELEPHONES This chapter describes the different modes of connection of a column/riser regardless of whether the column/riser is connected to an FA-Gtwin power supply, MC-Gtwin column multiplexer or DPM-Gtwin panel multiplexer. Connection of a column/riser with monitors/telephones and distributors distance between the D4L-Gtwin distributor and monitor/telephone.
  • Page 22 GTWIN SYSTEM MANUAL istanc Compatibility of cables and cross-sections of users RAP-GTWIN cable (for new installations) Telephone cable Ø 0.6 mm without cover CAT5 UTP (twisted pair) Max 4 HVV05-F cable hose 1.5 mm Cable cross-section 1 mm Connection of a column/riser with monitors/telephones in input/output mode maximum 32 monitors/telephones per column/riser Bv = distance between the device where the column/riser is connected and the furthest monitor/telephone.
  • Page 23 GTWIN SYSTEM MANUAL CONNECTION OF THE AUDIO DOOR ENTRY SYSTEM (1 BUILDING) This chapter describes the different connection modes of the door panels in systems with monitors (1 building). 1 column/riser with an access panel and 1 power supply column/riser maximum 127 users Ax+Bv Gtwin power supply Video door...
  • Page 24 GTWIN SYSTEM MANUAL § For information about the connection and distances of the column/riser, see the paragraph 'Connection of columns/risers with monitors/telephones.' istanc Compatibility of cables and cross-sections RAP-GTWIN cable (for new installations) 200m 800m Telephone cable Ø 0.6 mm without cover 100m 600m CAT5 UTP (twisted pair)
  • Page 25 GTWIN SYSTEM MANUAL The sum of all of the wiring of the Bus of door panels is obtained by the sum of parts E1+E2+E3+E4+D1, while the sum of all of the wiring of the column/riser Bus is obtained by the sum of parts Bv1+Bv2+Bv3+Bv4+A1+A2+...+An+D2.
  • Page 26 GTWIN SYSTEM MANUAL Sum of the 4 distribution No. of column istanc outputs of the DPM-Gtwin multiplexers Cable for each line G1+G2+G3+G4 RAP-GTWIN cable Max 8 600m 2400m For information about distances and the sum of all of the wiring of the installation Bus of each column multiplexer, see the paragraph '4 columns/risers with 1 column multiplexer, 1 power supply and 1 or 2 access panels.' System with general panels (main) with distribution over 2 outputs of the panel multiplexer...
  • Page 27 GTWIN SYSTEM MANUAL System with general panels (main) with distribution over 1 single output of the panel multiplexer using 8 D4L-Gtwin 4-user distributors. Column Column Column MC-Gtwin column multiplexer multiplexer multiplexer multiplexer Do not connect DPM-Gtwin panel multiplexer Cable H+L1+L2+...+L32 RAP-GTWIN cable Max 8 Max 32...
  • Page 28: Connection Of The Main Lock Release

    D4L-Gtwin 4-user distributor. Exception: If the column/riser has telephones only, it is possible to make electrical nodes. The use of other types of cable requires the prior approval of Golmar, according to the type of cables and distances of the project.
  • Page 29 GTWIN SYSTEM MANUAL Ÿ In the monitors/telephones, distributors and column multiplexer modules, there is a jumper that enables the end of line (Z) to be activated. It is necessary to activate the end of line in all of the devices where the Bus cable ends: Tekna Gtwin Z= ON...
  • Page 30: Activation Of The System

    GTWIN SYSTEM MANUAL ACTIVATION OF THE SYSTEM After wiring all of the devices of the site, carry out the following operations: 1. Configuration of devices with end of line. 2. Configuration of devices with DIP switch. 3. Turning on and checking the supply voltage. 4.
  • Page 31 GTWIN SYSTEM MANUAL Special attention must be paid to the configuration of the device codes. For the correct functioning of the system, take into account that: Ÿ Each door panel of the system must have a different code (called ID or Identification), which is set with the SW1 DIP switch using values from 0 to 3 if they are main, or from 0 to 31 if they are secondary.
  • Page 32 GTWIN SYSTEM MANUAL AUX: Auxiliary settings. Type of door panel: The door panel can be set as main (General) or secondary. From the main panel, you can call all of the apartments in the system; from the secondary panel, you can only call the apartments in the building (channel) to which it belongs.
  • Page 33 GTWIN SYSTEM MANUAL § The guaranteed communication time has to be set the same on all of the system's door panels. CONFIGURATION OF THE MONITORS/TELEPHONES CODE: User code. Set a number from 0 to 126, respecting the following rules: Ÿ In the column/riser, there should not be different apartments with the same user code. Ÿ...
  • Page 34 GTWIN SYSTEM MANUAL USER 54 USER 55 USER 56 USER 57 USER 58 USER 59 USER 60 USER 61 USER 62 USER 63 USER 64 USER 65 USER 66 USER 67 USER 68 USER 69 USER 70 USER 71 USER 72 USER 73 USER 74 USER 75...
  • Page 35 GTWIN SYSTEM MANUAL INT: Internal code of the monitor/telephone to set as master/slave. Set the monitor/telephone as master, slave 1, slave 2 or slave 3 using the SW2 DIP switch with a code from 0 to 3 respectively. Taking into account the following points: Ÿ...
  • Page 36: Turning On And Checking The Supply Voltage

    GTWIN SYSTEM MANUAL 3 TURNING ON AND CHECKING THE SUPPLY VOLTAGE Once adjustment of the ends of line (Z) and configuration of all of the devices have been completed, before mounting the monitors/telephones on the connectors, the system can be powered and the following checks carried out with the system in standby: FA-GTWIN power supply Check that each pair of LINE1 and LINE2 terminals have a direct voltage of 44 Vdc to 48 Vdc.
  • Page 37: Association Of Door Panel Buttons With Apartments

    GTWIN SYSTEM MANUAL EL-569 3 If a part of the connected section is disconnected by distributors, it is necessary to activate the end of line (Z) of the last distributor: Z= ON Z= ON LINE IN LINE IN LINE OUT LINE OUT Z= OFF Z= ON...
  • Page 38 GTWIN SYSTEM MANUAL But if the door panel is configured as main general and there are several column multiplexers (buildings/channels) in the system, it is necessary to programme the buttons to enable calls to be made to the apartments of the different buildings/channels of the site. Follow these steps: Set the SW3 and SW4 rotary DIPs on the EL632 Gtwin module to position 9.
  • Page 39: Basic Functional Check

    GTWIN SYSTEM MANUAL Button code DIP switch P2 P3 P4 P5 P6 P7 P8 P9 P10 Dip1 Dip2 Dip3 Dip4 Dip5 Dip6 Dip7 Dip8 1 1 2 1 1 3 1 1 4 1 1 5 1 116 117 118 119 120 EL606D (6 buttons).
  • Page 40: Optional Programming For Additional Functions

    GTWIN SYSTEM MANUAL 7 OPTIONAL PROGRAMMING FOR ADDITIONAL FUNCTIONS After checking the basic operation of the system, only if the following functions are required , it is necessary to carry out the corresponding programming operations. 1. Intercom function in the same apartment or between apartments: the user (apartment) code to be called or the internal code of the monitor (same apartment) to be called must be associated with the buttons.
  • Page 41 GTWIN SYSTEM MANUAL 4. Or go to a door panel and press the call button of apartment B; the monitor/telephone in programming (apartment A) emits a completed programming beep. While this operation is being carried out, the monitors/telephones in apartment B sound. Ignore this call. Apartment A APARTMENT B 5.
  • Page 42 GTWIN SYSTEM MANUAL INTERCOM FUNCTION WITHIN THE SAME APARTMENT To programme a monitor/telephone (internal device C1) to call another monitor/telephone (device C2) in the same apartment: Without picking up the handset. Press and hold key for more than 5 seconds: It emits 3 short tones and the slow blinking of the status LED (yellow) confirms entry into programming mode.
  • Page 43 GTWIN SYSTEM MANUAL heck the programmed function: lift the handset of the monitor/telephone (device C1) and press the programmed button. On the monitor/telephone (device C2), a ringtone will be heard, pick up the handset and check communication. 6. If you also wish to programme the reverse call, it is necessary to programme the monitor/telephone (device C2) for the call to the monitor/telephone (device C1) in the same apartment.
  • Page 44: Technical Characteristics Of The Devices

    GTWIN SYSTEM MANUAL TECHNICAL CHARACTERISTICS OF THE DEVICES D4L-GTWIN 4-user distributor Supply voltage: ..........................36 ÷ 48 Vdc Max absorption: ........................... 9 0mA max Operating temperature: ......................- 5° ÷ + 45° Dimensions: .......................... 45 x 45 x 16mm FA-GTWIN power supply Power supply: ....................110/ 230 Vac +/- 10 % 50/60 Hz Power: ..............................
  • Page 45 GTWIN SYSTEM MANUAL CONNECTION OF THE SECONDARY AC LOCK RELEASE To connect the 'Golmar' secondary lock release (max 12 ac/1 A) to the 'SE2' terminals (C and NO relay contacts), an additional TF-104 power supply, AL-Gtwin filter and PL-Gtwin line protector are required. As...
  • Page 46: Wiring Diagrams

    Configuration of the SAV-GTWIN call repeater, see p. 44. Connecting the FA-Gtwin power supply to the filter and line protector, see p. 44. Connecting the secondary AC lock release (Golmar), see p. 45. Main panel Video door entry system FA-GTWIN POWER SUPPLY LINE 1...
  • Page 47 Equipment/connection Columns 2, 3 and 4 as Connecting the FA-Gtwin power Column 1. supply to the filter and line protector, see p. 44. Connecting the secondary AC lock release (Golmar), see p. 45. LINE LINE Main panel Video door LINE...
  • Page 48 Connecting the FA-Gtwin power FA-GTWIN POWER SUPPLY supply to the filter and line protector, see p. 44. LINE 1 Connecting the secondary AC lock release (Golmar), see p. 45. LINE 2 MAIN GENERAL PANEL LINE~ LINE Exterior door opening button...
  • Page 49 GTWIN SYSTEM MANUAL One main general access, up to 16 buildings (16 MC-Gtwin multiplexers) and 2 secondary accesses in each building. (Maximum 127 monitors/telephones per building). BUILDING 1 BUILDING 2 COLUMN 3 COLUMN 4 COLUMN 5 COLUMN 6 COLUMN 7 COLUMN 8 COLUMNS 3-4 AS COLUMN 1 COLUMNS...
  • Page 50 LINE~ protector, see p. 44. Connecting the secondary AC lock (Connection of terminals (Connection of terminals as General Panel as General Panel release (Golmar), see p. 45. Main 'A') Main 'A') DPM-Gtwin panel multiplexer LINE LINE GENERAL PANEL...
  • Page 51 GTWIN SYSTEM MANUAL 4 main general accesses, up to 32 buildings (32 MC-Gtwin multiplexers) and 2 secondary accesses in each building. (Max. 127 monitors/telephones per building). BUILDING 1 BUILDING 2 COLUMN 3 COLUMN 4 COLUMN 5 COLUMN 6 COLUMN 7 COLUMN 8 COLUMNS 3-4 AS COLUMN 1 COLUMNS 5-6 AS COLUMN 1...
  • Page 52: Optional Connections

    2 lock releases. VIDEO DOOR ENTRY PANEL Connecting the F- 104 transformer to the filter and line protector, see p. 44. Connecting the secondary AC lock release (Golmar), see p. 45. LINE TOWARDS THE SYSTEM Exterior door SAR-12/18 opening button RELAY UNIT...
  • Page 53 GTWIN SYSTEM MANUAL OPTIONAL CONNECTIONS Additional call repeater with SAR-12/18 relay unit in monitor/telephone. MONITOR LINE LINE Connecting the F- 104 transformer to the filter and line protector, see p. 44. Apartment front door call TF-104 TRANSFORMER SAR-12/18 LINE~ RELAY UNIT LOAD 100V=/5A POWER SUPPLY...
  • Page 54: El569 In/Out Unit

    GTWIN SYSTEM MANUAL E 569 IN/OUT UNIT Tekna Gtwin monitor: The EL569 in/out unit must be inserted in all of the intermediate monitors and leave the J4 end of line jumper (Z) inserted in the last monitor (see p. 53). EL-569...
  • Page 55 GTWIN SYSTEM MANUAL EL 566 IN/OUT UNIT Tekna HF Gtwin/Tekna S Gtwin monitor: The EL566 in/out unit must be inserted in all of the intermediate monitors and leave the J2 end of line jumper (Z) inserted in the last monitor (see p. 53). EL-566...
  • Page 56: Compliance

    C/ Silici, 13 08940- Cornellá de Llobregat SPAIN Golmar se reserva el derecho a cualquier modificación sin previo aviso. Golmar se réserve le droit de toute modification sans préavis. Golmar reserves the right to make any modifications without prior notice.