INSTALLATION AND OPERATION GUIDE FOR
HARGROVE VENTED GAS LOGS
Installation and service must be provided by a qualified installer, service agency or the gas supplier.
NOTE:
ADEQUATE FIREPLACE VENTILATION IS REQUIRED FOR SAFETY.
READ INSTRUCTIONS FULLY BEFORE INSTALLING OR OPERATING.
INSTALLER: LEAVE THIS MANUAL WITH THE APPLIANCE.
CONSUMER: RETAIN THIS MANUAL FOR FUTURE REFERENCE.
WARNING:
If the information in this manual is not
followed exactly, a fire or explosion may
result, causing property damage, personal
injury, or loss of life.
WHAT TO DO IF YOU SMELL GAS
1. Open a window.
2. Do not try to light any appliance.
3. Do not touch any electrical switch; do not
use the phone in your building.
4. Immediately call your gas supplier from a
neighbor's
phone.
supplier's instructions.
5. If you cannot reach your gas supplier, call
the fire department.
FOR YOUR SAFETY
Do not store or use gasoline or other
flammable vapors and liquids in the vicinity of
this or any other appliance.
IMPORTANT:
Installation and service must
be performed by a qualified professional
installer, service agency, or the gas supplier.
NOTE:
This appliance is only for use with the
type of gas indicated on the rating plate.
Solid-fuels shall not be burned in a fireplace
where a decorative appliance is installed.
HIDDEN CONTROL(HC) (1T)
DESIGN CERTIFIED to ANSI Z21.60
Vented Decorative Appliance for Installation in
Solid-Fuel Burning Fireplaces.
Follow
the
This Hargrove vented gas log set is to be
installed only in a solid-fuel burning fireplace
with a working flue and constructed of
noncombustible material.
including provisions for combustion and
ventilation air must conform to the National
Fuel Gas Code, ANSI Z223.1/NFPA 54, or the
CSA B149.1, Natural Gas and Propane
Installation Code, and applicable local building
code. A damper clamp is included to maintain
the minimum permanent vent opening and to
prevent full closure of the damper blade. The
gas log set must be burned with the damper
completely open (In the Commonwealth of
gas
Massachusetts the damper must either be
welded in the fully open position or
completely removed) and the chimney free
of any obstructions or restrictions.
The realistic yellow flame produces carbon
monoxide and soot. Under normal conditions,
these products are exhausted up the chimney.
If fumes or soot, from the gas burning, are
evident in the room when the damper is fully
open it indicates that the fireplace draft is
defective. Do not operate your gas log set
until the fireplace draft is corrected. It is the
home-owners responsibility to assure their
fireplace has adequate draft.
ANSI
The installation,
REV 081718

Advertisement

Table of Contents
loading

Summary of Contents for Hargrove Hidden Control Series

  • Page 1 INSTALLER: LEAVE THIS MANUAL WITH THE APPLIANCE. CONSUMER: RETAIN THIS MANUAL FOR FUTURE REFERENCE. WARNING: This Hargrove vented gas log set is to be If the information in this manual is not installed only in a solid-fuel burning fireplace followed exactly, a fire or explosion may...
  • Page 2 IMPORTANT PRE-INSTALLATION AND FIREPLACE SAFETY INFORMATION WARNING: This appliance assembly contains burner orifices specifically for the input gas and Btu rating. Modifying or failure to use the factory orifice may cause property damage, personal injury or loss of life. 1. It is recommended that adults be present when this gas appliance is operating. It is recommended that this unit is not left burning when unattended or while anyone is sleeping.
  • Page 3: Specifications And Dimensions

    SPECIFICATIONS AND DIMENSIONS Each gas log set requires a minimum 18-inch front opening height and minimum 14-inch depth. To determine the largest set that will fit in a fireplace, the width at the front of the fireplace is the critical dimension. Table I below indicates the minimum front width for each size set. Back Width Front Width TABLE I...
  • Page 4: Pre-Installation Checklist

    PRE-INSTALLATION CHECKLIST FIREPLACE AND CHIMNEY  Fireplace is approved for solid-fuel burning and made of non-combustible materials.  Operational damper with a chimney free of any obstruction or restriction.  Fireplace has proper draft to accommodate decorative appliance.  Fireplace is free from debris or ash. ...
  • Page 5: Burner Parts List

    Non-Whistling Gas Flex Connector Damper Stop Glowing Embers Volcanic Cinder SD-10 Sand (NG sets only) Vermiculite (LP sets only) 49-6-6Z2 Orifice (NG sets only) AM3/8x3/8 Air Mixer (LP sets only) NOTE: Replacement parts can be ordered from your local Hargrove dealer.
  • Page 6: Gas Connection

    BURNER AND GRATE POSITIONING BURNER POSITION Check that the gas is turned off. Center the burner on the fireplace floor. The burner should be located under the flue opening. The grate should be placed over the burner so the front legs of the grate are just in front of the burner pipe.
  • Page 7: Lighting The Pilot

    LIGHTING THE PILOT Read the lighting instruction plate attached to the gas valve or located at Pilot Flame the end of these instructions. Push in gas control knob slightly and turn clockwise until the knob will not turn any Thermocouple longer.
  • Page 8: Grate Placement

    After allowing the logs to cool for at least one hour, the set can be burned for any length of time. LIMITED LIFETIME WARRANTY: Hargrove gas logs carry a limited lifetime warranty against breakage in the original fireplace.
  • Page 9 FOR YOUR SAFETY READ BEFORE LIGHTING WARNING: If you do not follow these instructions exactly, a fire or explosion may result causing property damage, personal injury or loss of life. A. This appliance has a pilot, which must be C. Use only your hand to push in or lit by hand.
  • Page 10 8. Purchaser or user agrees to hold Hargrove Mfg Corp. harmless from any and all claims by the buyer as a result of injury or damage to an ultimate user or other person caused by the product sold herein by the seller to the buyer, whether the injury or damage results from the assembly, installation, operation, shipment, storage, or manufacture of this product.