Specifications And Dimensions - Hargrove Hidden Control Series Installation And Operation Manual

Vented gas logs
Table of Contents

Advertisement

Each gas log set requires a minimum 18-inch front opening height and minimum 14-inch depth.
To determine the largest set that will fit in a fireplace, the width at the front of the fireplace is the
critical dimension. Table I below indicates the minimum front width for each size set.
SET SIZE
18"
24"
30"
36"
Free opening area of chimney damper for venting combustion products from decorative
appliances for installation in vented fireplaces. Minimum size of chimney flue is 8"
diameter.
Chimney
Height,
Feet

SPECIFICATIONS AND DIMENSIONS

Back Width
Front Width
MINIMUM
MINIMUM MINIMUM
FRONT WIDTH
30"
36"
42"
48"
TABLE II
Minimum Permanent Free Opening, Square Inches
29
Appliance Input Rating, Btu Per Hour (w)
6
34,000
8
37,000
10
40,400
15
44,600
25
50,400
30
55,200
TABLE I
DEPTH
HEIGHT
14"
18"
14"
18"
14"
18"
14"
18"
39
51
46,400
62,400
50,400
68,000
55,800
74,400
62,400
84,000
68,400
94,000
76,800
105,800
BTU(NG)
BTU(LP)
70,000
55,000
80,000
65,000
90,000
75,000
100,000
85,000
64
80,000
86,000
96,400
108,800
122,200
138,600
3

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Hc series