Hargrove LCK-RC Installation Instruction

Gas log latchtap kit

Advertisement

Quick Links

NOTE: This kit is used to upgrade a Manual Safety Pilot Kit (CPE-PO) to function using a
switching device (remote control, bark chip switch, or wall switch). Follow the Installation
Instructions in the CPE-PO kit for proper installation and operation.
USE THE PARTS LISTED BELOW WITH PARTS IN THE CPE-PO PILOT KIT
PART #
1.
CLC-BLOCK
2. 41S-6
3. SC-1
4. 68-6
5. N-6X1.5
6. LTHS
SWITCHING DEVICE FOR MATCHING KIT
LCK-RC (REMOTE CONTROL KIT)
A. RC-S6V-LT
1. (4) AA Batteries
f i r e - p a r t s . c o m
2. A23 Battery
LCK-BC (BARK CHIP KIT)
B. BPBCS
1. 9v BATTERY
LCK-WS (WALL SWITCH KIT)
C. WG-WS
1. (4) AA Batteries
LCK-WWS (WIRELESS WALL SWITCH KIT)
D. WS-S6V-LTST
1. (4) AA Batteries
2. CR2032
INSTALLATION
1.
Use the CPE-PO (Safety Pilot Valve Kit) Installation
Instruction to properly install the Extension Connector and
Pilot Assembly to the Ember Burner.
2. Attach the N-6X1.5 to the side port of the CLC-BLOCK.
3. Attach the other end of the N-6X1.5 to the outlet side of
the CPC-C
4. SC-1 assembly – Slide the 41S-6 onto the SC-1with both
flared ends going the same direction.
compression fitting to the SC-1 by sliding the nut and then
the ferule from the 68-6 onto the SC-1 then threading and
tightening the compression end of the 68-6 to the nut.
5. Attach the 68-6 end of the SC-1 assembly to the back port
of the CLC-BLOCK.
6. Verify that the brass elbow 49-6-6 is attached to the
ember burner and the flared end is facing forward. Attach
and tighten the 41S-6 end of the SC-1 to the 49-6-6.
7. Attach the wires on the CLC-BLOCK to the Switching
Device included in the LCK kit.
8. Assure the switching device is located as close to the
front opening of the fireplace and as far away from the
Ember Burner pan as possible.
9. Follow the Lighting Instructions in the CPE-PO Installation
instruction for proper lighting procedures.
IMPORTANT: GAS WILL NOT FLOW TO THE
EMBER BURNER UNTIL THE LATCHTAP (CLC-
BLOCK) IS ENGAGED USING ONE OF THE
SWITCHING DEVICES.
HARGROVE GAS LOG
LATCHTAP KIT (LCK-RC, LCK-BC,
LCK-WS, LCK-WWS)
INSTALLATION INSTRUCTION
DESCRIPTION
LATCHTAP BLOCK
BRASS FLARE NUT(included in CPE-PO)
STAINLESS TUBING(included in CPE-PO)
BRASS 3/8"FIP X 3/8" COMPRESSION
3/8 X 1.5 PIPE(included in CPE-PO)
LATCHTAP HEAT SHIELD
REMOTE CONTROL
NOT PICTURED
NOT PICTURED
BARK CHIP SWITCH
NOT PICTURED
WALL SWITCH
NOT PICTURED
WIRELESS WALL SWITCH
NOT PICTURED
NOT PICTURED
Attach the 68-6
6
D
A
HEAT SHIELD INSTALLATION
LTHS
CLC-BLOCK
LATCHTAP KIT
PILOT
EMBER
INSTALLED
ASSEMBLY
BURNER
49-6-6
CLC-BLOCK
2
5
3
4
1
B
C
PARTS INCLUDED IN
SAFETY PILOT KIT
41S-6
SC-1
68-6
CPC-C
SAFETY
PILOT
VALVE
(included
in CPE-PO
N-6X1.5

Advertisement

loading

Summary of Contents for Hargrove LCK-RC

  • Page 1 HARGROVE GAS LOG LATCHTAP KIT (LCK-RC, LCK-BC, LCK-WS, LCK-WWS) INSTALLATION INSTRUCTION NOTE: This kit is used to upgrade a Manual Safety Pilot Kit (CPE-PO) to function using a switching device (remote control, bark chip switch, or wall switch). Follow the Installation Instructions in the CPE-PO kit for proper installation and operation.
  • Page 2 OPERATION INSTRUCTIONS FOR YOUR SAFETY WARNING: If you do not follow these instructions exactly, a fire or explosion may occur resulting in property damage, personal injury, or loss of life. THIS APPLIANCE HAS A PILOT, WHICH MUST BE LIT BY HAND. WHEN LIGHTING THE PILOT, FOLLOW THESE INSTRUCTIONS EXACTLY.

This manual is also suitable for:

Lck-bcCk-wsLck-wws