HARGROVE VENTED GAS LOGS
Dexen Electronic Ignition Pilot Valve (DEI-PO)
Installation and service must be provided by a qualified installer, service agency or the gas supplier.
FOR YOUR SAFETY
WHAT TO DO IF YOU SMELL GAS
1. Open windows.
2. Extinguish all open flames.
3. Do not try to light any appliance.
4. Do not touch any electrical switch; do
not use the phone in your building.
5. Immediately call your gas supplier from
a neighbor's phone. Follow the gas
supplier's instructions.
6. If you cannot reach your gas supplier,
call the fire department.
WARNING
To avoid a potential fire hazard, do not
disassemble or attempt to repair the safety
gas valve. Disassembly, reassembly or
internal adjustment could cause the valve
to malfunction, resulting in property
damage, personal injury, or death. If the
control valve does not operate properly
following the installation or service,
replace the unit.
FOR YOUR SAFTEY
DO NOT STORE OR USE GASOLINE OR
OTHER
FLAMMABLE
FLAMMABLE VAPORS IN THE VICINITY OF
THIS OR ANY OTHER APPLIANCE
WARNING:
If you do not follow these instructions exactly, a fire or explosion may
occur resulting in property damage, personal injury, or loss of life.
INSTALLATION GUIDE FOR
LIQUIDS
OR
.
FOR YOUR SAFETY
CAUTIONS
1. This valve should be installed only by
a qualified service technician trained
in gas safety equipment.
2. Turn off the gas supply before
installing the valve.
3. All piping must meet applicable local
codes and ordinances and the
National Fuel Gas Code (ANSI
Z223.1/NFPA NO.54)
4. All wiring must meet the applicable
electrical codes and ordinances.
5. Assure that the complete system is
operating according to the
manufacturer's instructions after
installing the Parts Only Kit.
6. Prior to installation, verify
conformance with the log unit's
installation instructions.
7. Assure that all the piping is free of
any foreign matter.
INSTALLING A HARGROVE SAFETY GAS VALVE
IN A LOCATION OTHER THAN SPECIFIED IN THIS
MANUAL WILL VOID THE WARRANTY EXCEPT
WHEN THE SAFETY GAS VALVE IS INSTALLED
OUTSIDE THE FIREBOX IN A SAFE AND PROPER
INSTALLATION AND ACCESS IS PROVIDED FOR
MAINTENANCE AND REPAIR OF THE SYSTEM. A
QUALIFIED INSTALLER MUST MAKE
INSTALLATION AND ADJUSTMENTS.
PO
REV 122216

Advertisement

loading

Summary of Contents for Hargrove DEI-PO

  • Page 1 INSTALLATION GUIDE FOR HARGROVE VENTED GAS LOGS Dexen Electronic Ignition Pilot Valve (DEI-PO) Installation and service must be provided by a qualified installer, service agency or the gas supplier. CAUTIONS FOR YOUR SAFETY 1. This valve should be installed only by...
  • Page 2: Parts List

    PARTS LIST ITEM PART NUMBER DESCRIPTION DXMV-C ELECTRONIC IGNITION SAFETY VALVE HSRS225 VALVE HEAT SHIELD DEI-CHS CONTROL MODULE HEAT SHIELD ON/OFF SWITCH DXBP BATTERY PACK DXICM I/C MODULE PILOT ASSEMBLY 24” LEADS AFPI-24 DEI-PB PILOT MOUNTING BRACKET DXWH WIRING HARNESS FCNW-18 NON-WHISTLING GAS FLEX CONNECTOR 49-6 (2)
  • Page 3: Valve Connection

    VALVE CONNECTION Attach the 49-6-6Z2 (included in the burner accessory kit box) brass fitting to the burner pipe extending out of the right side of the burner pan (same end that the pilot is mounted on). Attach the 49-6 into the OUTLET end of the DXMV-C valve. Attach the FCNW-18 to the 49-6-6Z2 on the end of the pan.
  • Page 4: Troubleshooting

    MODULE/BATTERY LOCATION FIREPLACE FLOOR The Control Module and Battery Pack are sensitive to heat. Proper placement will help keep them from malfunctioning due to excess heat. See the “Parts List” pictures to see how to properly place the Control CONTROL Module and Battery Pack under the Heat Shield.
  • Page 5: Troubleshooting Chart

    TROUBLESHOOTING CHART START ENGAGE SWITCH TO CALL FOR HEAT DOES THE PILOT START TO SPARK CHECK LINE VOLTAGE, CHECK FOR 3V TRANSFORMER OUTPUT, ADAPTER CONNECTION WIRING, ETC. REPLACE MODULE AFTER PREPURGE IS THERE SPARK AT THE PILOT IS THERE ANY CHECK IGNITION WIRING AUDIBLE SPARK AND PILOT ASSEMBLY...
  • Page 6: Limited Warranty

    8. Purchaser or user agrees to hold Hargrove Mfg Corp. harmless from any and all claims by the buyer as a result of injury or damage to an ultimate user or other person caused by the product sold herein by the seller to the buyer, whether the injury or damage results from the assembly, installation, operation, shipment, storage, or manufacture of this product.