Supermicro SuperServer 1029GP-TR User Manual page 51

Table of Contents

Advertisement

Fan Fail and UID LED
Connect an LED cable to pins 7 and 8 of JF1 to use the Overheat/Fan Fail LED connections.
The LED on pin 8 provides warnings of overheat or fan failure.
OH/Fan Fail Indicator
Status
Status
Definition
Off
Normal
On
Overheat
Flashing
Fan Fail
NIC1/NIC2 (LAN1/LAN2)
The NIC (Network Interface Controller) LED connection for LAN port 1 is located on pins 11
and 12 of JF1, and the LED connection for LAN Port 2 is on pins 9 and 10. Attach the NIC
LED cables here to display network activity.
HDD LED
The HDD LED connection is located on pins 13 and 14 of JF1. Attach a cable to Pin 14 to
show hard drive activity status. Refer to the table below for pin definitions.
Chapter 4: Motherboard Connections
LAN1/LAN2 LED
Pin Definitions (JF1)
Pin#
Definition
9
NIC2 Activity LED
10
NIC2 Link LED
11
NIC1 Activity LED
12
NIC1 Link LED
HDD LED
Pin Definitions (JF1)
Pin#
Definition
13
3.3V Standby
14
HDD Active
51
OH/Fan Fail LED
Pin Definitions (JF1)
Pin#
Definition
7
Blue LED
8
OH/Fan Fail LED

Advertisement