MZ-N707
2. NV adjusted values modifying procedure
1) Select manual mode of the test mode, and set item number
336 (see page 14).
Set LCD display
3 36
: Adjusted value
[VOL +]
2) Adjust with the
key (adjusted value down) so that the adjusted value becomes
08.
3) Press the
X
key to write the adjusted value.
4) Select manual mode of the test mode, and set item number
741 (see page 14).
Set LCD display
7 41
: Adjusted value
[VOL +]
5) Adjust with the
key (adjusted value down) so that the adjusted value becomes
02.
6) Press the
key to write the adjusted value.
X
7) Select manual mode of the test mode, and set item number
771 (see page 14).
Set LCD display
7 71
: Adjusted value
[VOL +]
8) Adjust with the
key (adjusted value down) so that the adjusted value becomes
6E.
9) Press the
X
key to write the adjusted value.
10) Select manual mode of the test mode, and set item number
772 (see page 14).
Set LCD display
7 72
: Adjusted value
[VOL +]
11) Adjust with the
key (adjusted value down) so that the adjusted value becomes
7C.
12) Press the
key to write the adjusted value.
X
13) Select manual mode of the test mode, and set item number
773 (see page 14).
Set LCD display
7 73
: Adjusted value
20
[VOL --]
key (adjusted value up) or
[VOL --]
key (adjusted value up) or
[VOL --]
key (adjusted value up) or
[VOL --]
key (adjusted value up) or
[VOL +]
14) Adjust with the
key (adjusted value down) so that the adjusted value becomes
7D.
15) Press the
key to write the adjusted value.
X
16) Select manual mode of the test mode, and set item number
774 (see page 14).
Set LCD display
7 74
: Adjusted value
[VOL +]
17) Adjust with the
key (adjusted value down) so that the adjusted value becomes
7F.
18) Press the
X
key to write the adjusted value.
19) Select manual mode of the test mode, and set item number
775 (see page 14).
Set LCD display
7 75
: Adjusted value
[VOL +]
20) Adjust with the
key (adjusted value down) so that the adjusted value becomes
81.
21) Press the
key to write the adjusted value.
X
22) Select manual mode of the test mode, and set item number
776 (see page 14).
Set LCD display
7 76
: Adjusted value
[VOL +]
23) Adjust with the
key (adjusted value down) so that the adjusted value becomes
5B.
24) Press the
key to write the adjusted value.
X
25) Select manual mode of the test mode, and set item number
777 (see page 14).
Set LCD display
7 77
: Adjusted value
[VOL +]
26) Adjust with the
key (adjusted value down) so that the adjusted value becomes
7B.
27) Press the
X
key to write the adjusted value.
[VOL --]
key (adjusted value up) or
[VOL --]
key (adjusted value up) or
[VOL--]
key (adjusted value up) or
[VOL --]
key (adjusted value up) or
[VOL --]
key (adjusted value up) or
Need help?