29.2.4 System configuration 11
BWL-1S(B)
● Split air/water heat pump
● Separating cylinder
● One heating circuit
● DHW heating
DHW cylinder
SF
Indoor module
Outdoor module
A 3-way diverter valve for
central heating/DHW and a
feed/heating circuit pump
are integrated into the
indoor module
Important information:
In this schematic diagram, shut-off valves, air vent valves and safety equipment are not fully represented.
These should be provided for each system individually, in line with the applicable standards and regulations.
Hydraulic and electrical data can be found in the hydraulic system solutions technical guide.
3064298_201805
System configurations
HCP
Separating cylinder
Heating circuit
SAF
Please note:
Header temperature sensor SAF must be
installed in the return area of the low loss
header or separating cylinder.
75