Download Print this page

Electrical Installation - American Standard SELECTRONIC 606B2 Series Installation Instructions Manual

Concealed toilet flush valve 1.1. 1.28 & 1.6 gpf, exposed back spud/concealed back spud/top spud

Advertisement

ELECTRICAL INSTALLATION

STANDARD BATTERY POWER KIT
7
(PK00.CRP); Fig. 9, 10
1. Attach the SAFETY CHAIN (1) from the COVER PLATE (2)
to the MOUNTING POST (3) as shown. Fig. 9.
2. Connect one end of the 27" EXTENSION CABLE (1) to
SENSOR CABLE (2). Connect the other end of the 27"
EXTENSION CABLE (1) to the SOLENOID CABLE (3).
Fig.10.
3. Insert BATTERY (6) into BATTERY HOLDER (4), making
sure terminal side is inserted first. Fig.10.
4. Connect BATTERY HOLDER (4) to available SENSOR
CABLE (5) and install the CONNECTOR LOCKING DEVICE
(7). Place BATTERY HOLDER (4) into electrical box. Fig.10.
PWRX POWER KIT (PK00.WRK);
7a
Fig. 9, 10
1. Attach the SAFETY CHAIN (1) from the COVER PLATE (2)
to the MOUNTING POST (3) as shown. Fig. 9.
2. Connect one end of the 27" EXTENSION CABLE (1)
to SENSOR CABLE (2). Connect the other end of the 27"
EXTENSION CABLE (1) to the SOLENOID CABLE (3).
Fig.10.
3. Insert BATTERY (11) to available SENSOR CABLE (5)
and install the CONNECTOR LOCKING DEVICE (7).
Place BATTERY (11) to electrical box. Fig.10.
8
AC VERSION (PK00.PAC
Power Kit); Fig. 9, 10a
1. Attach the SAFETY CHAIN (1) from the COVER
PLATE (2) to the MOUNTING POST (3) as shown.
Fig. 9.
2. Connect one end of the 27" EXTENSION
CABLE (4) to SENSOR CABLE (5). Connect
the other end of the 27" EXTENSION CABLE (4)
to the SOLENOID CABLE (6). Fig.10a.
3. Connect the second 27" EXTENSION
CABLE (7) to the AC POWER SUPPLY (8), and
the other end of the 27" EXTENSION CABLE (7)
to available SENSOR CABLE (9). Fig.10a.
4. Plug AC POWER SUPPLY (8) into outlet. Fig. 10a.
FOR HARD-WIRED VERSION
(PK00.HAC POWER KIT)
7. Contractor to supply ELECTRICAL BOX (11).
8. Connect black and white power line connections
to HARD-WIRED AC TRANSFORMER (12) and
mount onto ELECTRICAL BOX (11).
NOTE: CONNECTOR LOCKING DEVICE not used
for AC installation.
Fig. 9
Fig. 10
1
Fig. 10a
7
4
5
9
8
11
6
ELECTRICAL
OUTLET
4" CONTROL BOX
OR EQUIVALENT BY
OTHERS (6)
7
T O P
1
2
6
TERMINAL SIDE
4
11
2
5
3
7
4a
27' EXTENSION
BLACK & WHITE
POWER
12
CONNECTIONS
M965640 Rev. 1.4 (11/17)