Download Print this page
American Standard SELECTRONIC 6065.561 Installation Instructions Manual
American Standard SELECTRONIC 6065.561 Installation Instructions Manual

American Standard SELECTRONIC 6065.561 Installation Instructions Manual

Proximity dual flush toilet flush valve

Advertisement

Quick Links

SELECTRONIC™
PROXIMITY DUAL FLUSH TOILET FLUSH VALVE
1.6 / 1.1 GPF, 1.28/1.1 GPF
Certified to comply with ASME A112.19.2M
© 2010 AS America, Inc.
M965051 REV.1.5
NOTE TO INSTALLER: Please give this manual to the customer after installation.
To learn more about American Standard Faucets visit our website at: www.americanstandard-us.com
or U.S. customer's e-mail us at: faucetsupport@americanstandard.com
For Parts, Service, Warranty or other Assistance,
1-800-442-1902 (In Canada: 1-800-387-0369)
please call
Exposed Flushometer for 1-1/2" Top Spud Bowls
This flushometer valve is intended to be used with
listed/certified 1.6gpf / 1.1gpf dual flush bowls only.
CLOG RESISTANT
CLOG RESISTANT
• Self-cleaning piston valve prevents clogging and reduces maintenance.
• Self-cleaning piston valve prevents clogging and reduces maintenance.
ONE SENSOR FITS ALL
ONE SENSOR FITS ALL
• Only 1 sensor for entire Selectronic™ line of faucets, urinals, and ush valves.
• Only 1 sensor for entire Selectronic™ line of faucets, urinals, and ush valves.
• Range can be adjusted manually or with optional remote control.
• Range can be adjusted manually or with optional remote control.
• Sensor Features Low Battery Indicator.
• Sensor Features Low Battery Indicator.
(In Toronto Area only: 1-905-3061093)
(In Toronto Area only: 1-905-3061093)
MODEL NUMBERS
6065.561
6065.761
6065.721
6065.521

Advertisement

loading

Summary of Contents for American Standard SELECTRONIC 6065.561

  • Page 1 M965051 REV.1.5 NOTE TO INSTALLER: Please give this manual to the customer after installation. To learn more about American Standard Faucets visit our website at: www.americanstandard-us.com or U.S. customer's e-mail us at: faucetsupport@americanstandard.com For Parts, Service, Warranty or other Assistance,...
  • Page 2: Care Instructions

    M965051 REV.1.5 NOTE TO INSTALLER: Please give this manual to the customer after installation. To learn more about American Standard Faucets visit our website at: www.americanstandard-us.com or U.S. customer's e-mail us at: faucetsupport@americanstandard.com For Parts, Service, Warranty or other Assistance,...
  • Page 3: General Description

    Fig. 1 GENERAL DESCRIPTION: Roughing-in Dimensions SELECTRONIC™ PROXIMITY TOILET DETECTION ZONE FLUSH VALVE 400mm-800mm (15-3/4 TO 31-1/2) Exposed Flushometer for 1-1/2" Top Spud Fixtures 72mm FINISHED WALL (2-7/8) Exclusive, self cleaning piston-type 57mm (2-1/4 MIN.) flush valve with proximity operation and manual override.
  • Page 4 INSTALL THE SWEAT SOLDER Fig.3 ADAPTER; Fig. 3 FINISHED WALL CENTER LINE OF Turn water supplies off CAUTION FIXTURE SPUD before beginning Note: Install Optional Sweat Solder Adapter (Supplied) for copper pipe supply line. Fig. 3. (A-B)= 1. Measure the distance (A) from the finished wall to the 32mm center of the inlet spud on the fixture.
  • Page 5 FLUSH OUT SUPPLY LINES; Fig. 6 Fig. 6 1. Remove COVER (1) from SUPPLY STOP (2). REMOVE COVER 2. With a flat blade screwdriver open SUPPLY STOP (2). 3. Turn on water supply to flush line of any debris or sediment.
  • Page 6 INSTALL FLUSH VALVE; Fig. 8a Fig. 8a & 8b 1. As shown in Fig. 8a, insert the side INLET FLANGE (1) on the FLUSH VALVE (2) into the SUPPLY STOP (3). Lubricate the INLET FLANGE O-RING (4) with water if necessary.
  • Page 7: How To Change The Battery

    If these items do need replacement they must be purchased separately or order the complete flush valve assembly from American Standard. 1. Remove COVER (1) from SUPPLY STOP (2) if installed. Fig. 10.
  • Page 8 HOW TO SET DETECTION RANGE Fig. 13 (If Required); (purchased after May 2013) Fig. 13 & 14 Fig. 13b Fig. 13a Note: The detection distance is preset and is ideal for most installations. Should an adjustment be required follow the steps below. 1.
  • Page 9 HOW TO SET DETECTION RANGE Fig. 15 (If Required) ; (purchased before June 2013) Fig. 15 & 16 Note: The detection distance is preset and is ideal for Fig. 15a Fig. 15b most installations. Should an adjustment be required follow the steps below. 1.
  • Page 10 M965051 REV.1.5...