INSTALLATION INSTRUCTIONS
BABY DEVORO FLUSHOMETER BOWL
Model 2282
Thank you for selecting American Standard – the benchmark of fine quality for over 100 years. To ensure this product is installed
properly, please read these instructions carefully before you begin. (Certain installations may require professional help.) Also be
sure your installation conforms to local codes.
CAUTION: PRODUCT IS FRAGILE. TWO PEOPLE ARE RECOMMENDED FOR HANDLING TO AVOID
!
BREAKAGE AND POSSIBLE INJURY!
NOTE: For proper operation product requires a minimum of 30 psi working line pressure
RECOMMENDED TOOLS AND MATERIALS
Putty Knife
Flush Valve
1
Pictures may not exactly define contour of china
Model 2282
FINISHED WALL
254mm
(10")
C/L OF OUTLET
4
FLANGE
POSITION TOILET ON FLANGE
a. Unplug floor waste opening and install toilet on closet
flange so bolts project through mounting holes.
b. Loosely install retainer washers and nuts. Side of
washers marked "THIS SIDE UP" must face up!
P r o d u c t n a m e s l i s t e d h e r e i n a r e
t r a d e m a r k s o f A S A m e r i c a s I n c .
© A S A m e r i c a s I n c . 2 0 11
Regular Screwdriver
Adjustable Wrench
1" N.P.T. OR 1" C.W.T. SUPPLY
TO FLUSH VALVE
121mm
(4-3/4")
546mm
(21-1/2")
1 - 1/2
SPUD
FINISHED
FLOOR
NUT
TAPERED
WASHER
CLOSET
BOLT
In the United States:
American Standard Brands
P.O. Box 6820
Piscataway, New Jersey 08855
Attention: Director of Customer Care
For residents of the United States, warranty
information may also be obtained by calling
the following toll free number: (800) 442-1902
www.americanstandard.com
Sealant
Tape Measure
2
CLOSET
FLANGE
10"
254mm
CLOSET
BOLTS
INSTALL CLOSET BOLTS
Install closet bolts in flange channel, turn
90°, and slide into place 6" (152mm) apart
and parallel to wall.
5
BOLT
CAP
CLOSET
BOLT
WASHER
NUT
INSTALL TOILET
a. Position toilet squarely to wall and, with a rocking motion, press bowl down fully on
wax ring and flange. Alternately tighten nuts until toilet is firmly seated on floor.
CAUTION: DO NOT OVERTIGHTEN NUTS
!
b. Install caps on washers. (If necessary, cut bolt height to size before installing caps.)
c. Smooth off the bead of sealant around base. Remove excess sealant.
In Canada:
AS Canada, ULC
5900 Avebury Rd.
Mississauga, Ontario
Canada L5R 3M3
Toll Free: (800) 387-0369
www.americanstandard.ca
Carpenters Level
3
SEALANT
INSTALL WAX SEAL
Invert toilet on floor (cushion to prevent
damage), and install wax ring evenly
around waste flange (horn), with
tapered end of ring facing toilet. Apply a
thin bead of sealant around toilet base.
CLOSET FLANGE
OR BASE MAY BE DAMAGED!
American Standard B&K Mexico
S. de R.L. de C.V.
Via Morelos #330
Col. Santa Clara
Ecatepec 55540 Edo. Mexico
Toll Free: 01-800-839-1200
www.americanstandard.com.mx
WAX RING
In Mexico:
7301876- 100

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the SELECTRONIC 6065.121 and is the answer not in the manual?

Questions and answers

Summary of Contents for American Standard SELECTRONIC 6065.121

  • Page 1 Model 2282 Thank you for selecting American Standard – the benchmark of fine quality for over 100 years. To ensure this product is installed properly, please read these instructions carefully before you begin. (Certain installations may require professional help.) Also be sure your installation conforms to local codes.
  • Page 2: Instrucciones De Instalación

    BABY DEVORO TAZA DE FLUXOMÉTRO Model 2282 Gracias por elegir American Standard - el parámetro de primera calidad por más de 100 años. Para asegurarse de que el producto esté instalado correctamente, por favor lea estas instrucciones cuidadosamente antes de comenzar. (Ciertas instalaciones pueden requerir ayuda profesional).
  • Page 3: Instructions D'installation

    ROBINET DE CHASSE Model 2282 Nous vous remercions d'avoir choisi American Standard - synonyme de qualité supérieure depuis plus de 100 ans. Afin de s'assurer que ce produit soit bien installé, veuillez lire ces instructions attentivement avant de commencer. (Certaines installations peuvent requérir une aide professionnelle.) Assurez-vous également que votre installation se conforme aux codes locaux.
  • Page 4 © 2015 AS America, Inc. NOTE TO INSTALLER: Please give this manual to the customer after installation. Products visit our website at: www.americanstandard-us.com To learn more about American Standard Selectronic ® or e-mail us at: CRTTEAM@americanstandard.com For Parts, Service, Warranty or other Assistance,...
  • Page 5: Care Instructions

    Thank you for selecting American-Standard...the benchmark of fine quality for over 100 years. To ensure that your installation proceeds smoothly--please read these instructions carefully before you begin. All American Standard Products Are Water Tested At Our Factory. UNPACKING Some Residual Water May Remain In The Valve During Shipping.
  • Page 6: General Description

    (6") MIN. FOR 1-1/2" TOP (6-11/16") MÁX. SPUD FIXTURES CAUTION: Use only American Standard supplied transformers and cable sets. Using non-AS supplied cables, or cutting, splicing or modifying any components *Note: The Critical Line (-C-L-) on Vacuum will void the warranty.
  • Page 7 Fig. 3 FLUSH VALVE INSTALLATION FINISHED WALL CENTER LINE OF FIXTURE SPUD INSTALL SWEAT ADAPTER; Fig. 3 Turn water supplies off before CAUTION beginning (A-B)= Note: Install Optional Sweat Adapter (Supplied) for 32mm copper pipe supply line. (1-1/4") FILE EDGES 1.
  • Page 8 FLUSH OUT SUPPLY LINES; Fig. 6 Fig. 6 1. Remove STOP VALVE COVER (1) from STOP VALVE (2). REMOVE COVER 2. Open STOP VALVE (2) with a flat blade screwdriver. 3. Turn on water supply to flush line of any debris or sediment. 4.
  • Page 9: Maintenance

    If these items do need replacement they must be purchased separately or order the complete flush valve assembly from American Standard. 1. Remove STOP VALVE COVER (1) from STOP VALVE (2). 2. Turn water supply off.
  • Page 10 REPLACE BATTERY; Fig. 11, 11a Fig. 11 1. Loosen SET SCREW (1) with 2.5mm Hex Wrench (2) in back of FLUSH VALVE COVER (3). Fig. 11. 2. Rotate COVER (3) to the right and pull off. Fig. 11. 3. Turn COVER (3) over and disconnect the SENSOR (4) from the BATTERY HOLDER (5).
  • Page 11 SET DETECTION RANGE Fig. 13 (If Required); Fig. 13 y 14 Note: The detection distance is preset and ideal for most installations. Should an adjustment be required, follow the steps below. 1. Loosen SET SCREW (1) with 2.5mm Hex Wrench (2) in VIEW “A”...
  • Page 12: Troubleshooting Flowcharts

    P ro d uc t n a me s l i st e d he re i n are t r a d e ma r ks o f A S A m er i ca , In c . ©20 1 5 AGAIN TO PRIME THE VALVE. To learn more about American Standard Selectronic® Products visit our website at: DOES FLUSHING STOP? www.americanstandard-us.com or e-mail us at: CRTTEAM@americanstandard.com...
  • Page 13 Pro duct nam es lis ted herein are tra demar ks of AS Ame rica , I n c . ©2 0 1 5 To learn more about American Standard Selectronic® Products visit our website at: www.americanstandard-us.com or e-mail us at: CRTTEAM@americanstandard.com...

Table of Contents