18. Characteristics and technical data (continuation)
Inverter
Environmental
Ambient temperature range
Relative humidity
Acoustic noise emission level
Maximum operating altitude without derating
Environmental pollution degree classification for external environments
Environmental class
Suitable for wet location
Physical
Environmental protection rating
Cooling
Dimension (H x W x D)
Weight
Mounting system
Overvoltage rating as per IEC 62109-1
Safety
Safety class
Insulation level
Marking
Safety and EMC Standards
Grid standard (check your sales channel for availability)
Other features
Load manager
AC backup output, off grid
Battery charge from AC
AC-coupled
Battery Unit
Modules manufacturer
Battery type
Total energy
Maximum battery voltage (Vdc max)
Battery voltage range (Vdc operating range)
Maximum DC charge current (Idc max charge)
Maximum DC discharge current (Idc,max discharge)
Deep of discharge (DoD)
N° of battery unit that can be connected to the REACT2-UNO inverter
Charge power
Discharge power
Environmental
Environmental protection rating
Ambient temperature range
Suggested ambient temperature
Storage temperature
Relative humidity
Physical
Cooling
Dimension (H x W x D)
Weight
Mounting system
Safety
Protective class
Marking
Safety
Energy meter
REACT-MTR-1PH
ABB B21-212
ABB B23-212
ABB B24-212
1) Refer to the document "String inverter – Product Manual appendix" available at www.abb.com/ solarinverters to know the brand and the model of the quick fit connector"
2) For VDE-AR-N 4105 setting, maximum active power of 4600 W and maximum apparent power of 4600 VA
3) The AC voltage range may vary depending on specific country grid standard
4) The Frequency range may vary depending on specific country grid standard
5) As per IEEE 802.11 b/g/n standard
6) In the event of a fault, limited by the external protection envisaged on the AC circuit
Remark. Features not specifically listed in the present data sheet are not included in the product
REACT2-UNO-3.6-TL
-20...+55°C
with derating above 50°C
4...100 % condensing
< 50 dB (A) @ 1 m
2000 m / 6560 ft
740 mm x 490 mm x 229 mm
II (DC input) III (AC output)
IEC/EN 62109-1, IEC/EN 62109-2, EN 61000-6-2,
EN 61000-6-3, EN 61000-3-2, EN 61000-3-3, EN61000-3-11, EN61000-3-12
CEI 0-21, DIN V VDE V 0126-1-1, VDE-AR-N 4105, G83/2, G59/3, RD 413,
AS/NZS 4777.2,C10/11, IEC 61727, IEC 62116
Yes, with two integrated relays
Yes, it can be enabled
4.5 A for each battery installed
5.6 A for each battery installed
1.6 kW, 3.2 kW, 4.8 KW
2 kW, 3.6 kW, 3.6 kW (REACT2-3.6-TL-OUTD)
2 kW, 4 kW, 5 kW (REACT2-5.0-TL-OUTD)
IP54 (suggested indoor installation for preserving battery life time)
-20...+55°C (out of 0...+40°C temperature range, battery will be disabled)
-20...+25°C (6 months) or -20...+45°C (3 months)
4...100 % condensing
740 mm x 490 mm x 229 mm
IEC 62619, UN38.3, UN3480
Single-phase, 20A
Single-phase, 65A
Three-phase, 65A
Three-phase with external CT (opt.)
- 25 -
REACT2-UNO-5.0-TL
-20...+55°C
with derating above 45°C
3
Outdoor
Yes
IP65
Natural
< 22 kg
Wall bracket
I
Transformerless
CE
Yes
Yes
REACT2-BATT
Samsung
Li-Ion
4 kWh
575 V
170...575 V
95%
1, 2, 3
+5...+30°C
Natural
50 kg
Wall bracket
I
CE
EN