5. Choice of installation location (continuation)
•   Do not install in rooms where people live or where the prolonged presence of people or animals is expected, because of the noise that
the system produces during operation The level of the sound emission is heavily influenced by where the appliance is installed (for
example: the type of surface around the inverter, the general properties of the room, etc.) and the quality of the electricity supply.
•   Avoid electromagnetic interference that can compromise the correct operation of electronic equipment, with the consequent hazards
•   The ambient temperature of the installation location should be between 5°C and 30°C to guarantee the optimal operation of the battery unit
(REACT2-BATT). Here below are the functions available from the system on the basis of the ambient temperature:
T1 - Optimal operation of the REACT2 system
T2 - Correct operation of the REACT2 system with possible reduction of power
T3 - Operation limited to the inverter part only. Management of the battery is disabled.
T3
-20
-10
•  
•   Hardware and software maintenance on REACT2-UNO entails opening the front cover. Check that the correct installation safety distances are
observed in order to allow routine check and maintenance operations.
•   Install on a wall or strong structure suitable to bear the weight.
•   Install at a height which takes into consideration the weight of the appliance and in a position which is suitable for servicing, unless suitable
means are provided to carry out the operation.
•   If possible, install at eye-level so that the synoptic can be seen easily.
•   The inverter can be commissioned and monitored using the wireless communication channel. The WLAN uses radio waves to transmit and
receive data, it is therefore important to find a position for the router considering the different materials which the radio signal will have to pass
through:
Material
Open field
Wood / Glass
Stone / Plywood
Reinforced concrete
Metal
Final installation of the inverter must not compromise access to any externally located disconnection devices.
6. Mounting Instructions
Wall installation of the REACT2 system
•   Position the REACT2-UNO bracket
vel on the wall and use it as a drilling template.
•   It is the installer's responsibility to choose an appropriate type of screw anchors for the attach-
ment points. The choice must be based on the type of support (wall, frame or other support),
the type of anchors to be used, and their ability to support 4 times the inverter's weight
(4x22Kg=88Kg).
Depending on the type of anchor chosen, drill the required 2 holes
•   Install the REACT2-UNO bracket
2 x
9 mm
Ø
20
B
B
T2
0
+5
Relative signal reduction
0% (strength of approximately 40 meters)
From 0 to 10%
From 10 to 40%
From 60 to 90%
Up to 100 %
01
so that it is perfectly le-
01
to the support.
The underlying procedure is related to the side-by-side installation of REACT2-BATT.
Alternatively, is possible to install the REACT2-BATT separately and at greater distan-
ces using the "REACT2-XL-CABLE-KIT" cable kit (2 meter cables length).
•   Position the REACT2-BATT bracket
template. To aling the two brackets use the reference point and follow the steps as in the picture.
01
•   It is the installer's responsibility to choose an appropriate type of screw anchors for the attach-
ment points. The choice must be based on the type of support (wall, frame or other support),
the type of anchors to be used, and their ability to support 4 times the inverter's weight
(4x50Kg=200Kg).
•   Depending on the type of anchor chosen, drill the required 2 holes
•   Install the REACT2-BATT bracket
T1
T2
+30
to mount the bracket.
A
20
so that it is perfectly level on the wall and use it as a drilling
20
to the support.
- 7 -
T3
+40
+55
2 x
9 mm
Ø
A
B
to mount the bracket.
(Continue to next page)
EN
°C
01
A