18. Characteristics and technical data

System components of REACT2 photovoltaic system with storage
Inverter unit
Battery unit
Energy meter
Inverter
PV port
Absolute maximum DC input voltage (Vdc, max)
Start-up DC input voltage (Vstart)
Operating DC input voltage range (Vdcmin...Vdcmax)
Rated DC input voltage (Vdcr)
Rated DC input power (Pdcr)
Number of Independent MPPT
Maximum DC input power for each MPPT (PMPPTmax)
DC input voltage range with parallel configuration of MPPT at
Pacr, not operative battery
Maximum DC input current (Idc max) / for each MPPT (IMPPTmax)
Maximum input short circuit current for each MPPT (Iscmax)
Maximum Return current (AC side vs DC side)
Number of DC input connection pairs for each MPPT
DC connection type
PV port protection
Reverse polarity protection
Input overvoltage protection for each MPPT - varistor
Photovoltaic array isolation control
DC switch rating for each MPPT
Output AC port
AC grid connection type
Rated AC power (Pacr @cosφ=1)
Maximum AC output power (Pacmax @cosφ=1)
Maximum apparent power (Smax)
Rated AC grid voltage (Vac,r)
AC voltage range
Maximum AC output current (Iac,max)
Contributory fault current
Inrush current
Rated output frequency (fr)
Output frequency range (fmin...fmax)
Nominal power factor and adjustable range
Total current harmonic distortion
AC connections type
Output AC port protection
Anti-islanding protection
Maximum external AC overcurrent protection
Output overvoltage protection - varistor
Backup output port
AC grid connection type
Maximum apparent power (Smax)
Rated AC grid Voltage (Vacr)
AC Voltage range
Maximum AC output current (Iac max)
Rated output frequency (fr)
Output frequency range (fmin...fmax)
AC connections type
Backup output protection
Maximum external AC overcurrent protection
Output overvoltage protection - varistor
Input AC port
AC voltage range
Maximum AC input current (Iac max)
Inrush current
Rated output frequency (fr)
Battery port
Operating DC input voltage range (Vdcmin...Vdcmax)
Maximum DC charge current (Idc,max charge)
Rated AC grid Voltage (Vacr)
Operating performance
Maximum efficiency (ηmax)
Weighted efficiency (EURO/CEC)
Embedded communication
Embedded physical interface
Embedded communication protocols
Datalogger data retention
Remote monitoring
Local monitoring
REACT2-3.6-TL-OUTD
REACT2-UNO-3.6-TL
REACT-MTR-1PH; ABB B21-212; ABB B23-212; ABB B24-212
REACT2-UNO-3.6-TL
0.7 x Vstart ...575 V (min 90 V)
5000 W
2500W Linear derating
[480 V≤VMPPT≤575 V]
160 V...480 V
24 A / 12 A
Negligible in normal operating conditions
Quick-fit PV connector
Yes, from current limited source
According to local standard
3600 W
3600 W
3600 VA
16 A
16A
45...55 Hz / 55...65 Hz
> 0.995, adj. ± 0.1 - 1 (over/under exited)
According to local standard
20 A
45...55 Hz / 55...65 Hz
16 A
13.5 A
10 A
96.3% / -
Wireless
Modbus TCP (SunSpec), Modbus RTU (Sunspec), ABB-free@home ®
Web server user interface
- 24 -
REACT2-5.0-TL-OUTD
REACT2-UNO-5.0-TL
REACT2-BATT
REACT2-UNO-5.0-TL
575 V
200 V (adj. 120...350 V)
390 V
6000 W
2
3000W Linear derating
[480 V≤VMPPT≤575 V]
195 V...480 V
27 A / 13.5 A
15 A
(6)
2
(1)
Yes
25 A / 575 V
Single-phase
5000 W
5000 W
5000 VA
230 V
180...264 V
(3)
22 A
22A
Negligible
50 Hz / 60 Hz
(4)
<3%
Panel connector
25 A
2 (L - N / L - PE)
Single-phase
3000 VA
230 V
180...264 V
(3)
13 A
50 Hz / 60 Hz
(4)
Screw terminal block
16 A
2 (L-N/L-PE)
230 V
22 A
Negligible
50 Hz / 60 Hz
170 V...575 V
13.5 A
10 A
97.1%
96.6% / -
, 2 x Ethernet, RS485
(5)
30 days
Mobile app
(Continue to next page)
EN
(2)
(2)
(2)

Advertisement

Table of Contents
loading