Specifications; Environmental Specifications; Mechanical Specifications; Power Supply Specifications - HP HPE ProLiant DL180 Gen10 Maintenance And Service Manual

Table of Contents

Advertisement

Specifications

Environmental specifications

Specification
Temperature range
Operating
Nonoperating
Relative humidity (noncondensing)
Operating
Nonoperating
1
All temperature ratings shown are for sea level. An altitude derating of 1.0°C per 305 m (1.8°F per 1000 ft) to 3050 m
(10,000 ft) is applicable. No direct sunlight allowed. Maximum rate of change is 20°C per hour (36°F per hour). The
upper limit and rate of change might be limited by the type and number of options installed.
For certain approved hardware configurations, the supported system inlet temperature range is extended:
5°C to 10°C (41°F to 50°F) and 35°C to 40°C (95°F to 104°F) at sea level with an altitude derating of
1.0°C per every 175 m (1.8°F per every 574 ft) above 900 m (2953 ft) to a maximum of 3050 m
(10,000 ft).
40°C to 45°C (104°F to 113°F) at sea level with an altitude derating of 1.0°C per every 125 m (1.8°F
per every 410 ft) above 900 m (2953 ft) to a maximum of 3050 m (10,000 ft).
The approved hardware configurations for this system are listed on the Hewlett Packard Enterprise
website.

Mechanical specifications

Dimension
Height*
Depth*
Width*
Weight (approximate range)
* These dimensions apply to all server models.

Power supply specifications

Depending on the installed options and the regional location where the server was purchased, the server
can be configured with one of the following power supplies:
148
Specifications
1
Value
10°C to 35°C (50°F to 95°F)
-30°C to 60°C (-22°F to 140°F)
8% to 90%
28°C (82.4°F), maximum wet bulb temperature
5% to 95%
38.7°C (101.7°F), maximum wet bulb temperature
Value
8.75 cm (3.44 in)
63.47 cm (24.99 in)
44.54 cm (17.54 in)
13 kg to 26 kg (28 lb to 58 lb)