Under no circumstances is the Tuscany to be installed at less than 1.8m (71") from the floor. Consideration should
be given to any temporary or occasional additions such as stages or platforms and adjusted accordingly. For
outdoor use, or other areas with air movement/wind the directional Infrared spread may reduce by 1/3 to 1/2.
Wall/ceiling mount swivel brackets are provided with the heater which has been specifically designed to allow this
product to be fitted to a wall or ceiling with adequate clearances at the back of the unit. Do not mount the heater
with any other bracket except those provided.
The sides and ends of the heater must always be at least 500mm (19.6") away from the nearest wall, ceiling or
other structure.

INSTALLATION:

Diagram 1: Correct Wall / Ceiling Position
Diagram 2: Installation using a stand
The Tuscany may be installed on its own stand (available separately). Installation is easy using the brackets
supplied following the diagrams below.
The heater incorporates a tip-over function which will cut the power if the unit detects an angle greater than 45°.
CAUTION:
Ensure mains power is OFF before commencing installation.
The supplied mains cable must not contact the top surface of the heater during operation.
Heater must not be located immediately below a socket outlet. Electrical connections must be made outside of
the footprint of the unit to avoid heat build-up. If the heater is to be mounted on an incline (e.g. sloping
roof), ensure the electrical connection is located below the lowest end of the heater.
Joists, beams and rafters shall not be cut or notched to install the appliance.
This heater is not intended for ceiling-recessed installation. Do not install pointing directly downwards.
The identification mark and model reference should be visible after installation.
The Tuscany must not be attached facing or close to any combustible material (eg, wood or PVC cladding,
fascia or soffit) or other materials that could blow onto the heater.
The fixed wiring insulation coming into contact with parts with a temperature rise of greater than 50°C must
be protected, for example, by sleeving having an appropriate temperature rating.
Exercise caution when siting the heater stand that the heater cannot accidentally be touched, knocked-over or
that the wire causes a tripping hazard.
Never place the stand and heater next to a swimming pool, pond or other water source.